On the Photometric Consequences of Charge-Transfer Inefficiency in WFPC2
نویسنده
چکیده
Charge-transfer effects in photometry with Wide Field Planetary Camera 2 aboard the Hubble Space Telescope are investigated by a comparison of WFPC2 observations with groundbased photometry for the Galactic globular clusters ω Centauri and NGC2419. Simple numerical formulae describing the fraction of lost signal as functions of position on the detector, stellar brightness, and the diffuse sky brightness recorded in an image are presented, and the resulting corrections are compared to those previously derived by Whitmore & Heyer (1997, Instrument Science Report WFPC2 97-08). Significant lost-charge effects are seen that are proportional to both the Y coordinate (i.e., the number of shifts along the parallel register during readout) and the X coordinate (number of shifts along the serial register). A “typical” star image (one containing ∼ 10 photoelectrons) near the center of a “typical” intermediate-length exposure (one with a diffuse sky brightness of ∼ 10 e/pixel, obtained at a camera temperature of –88C) loses approximately 2% of its electrons to charge traps during readout; a star in the corner of the image most remote from the readout electronics loses twice that. The percentage of charge lost decreases as the star brightness or the diffuse sky brightness increases. Charge losses during the brief period when WFPC2 was operated at a temperature of –76C were approximately 85% greater, but apart from that no significant change in the charge transfer losses with time during the first 3.5 years of WFPC2’s mission is evident, except possibly a weak effect for the very faintest star images. These results are quite similar to those of Whitmore & Heyer, which were based on a much smaller data set, but there are some differences in detail. Even with the present set of corrections, additional sources of calibration uncertainty which I am unable identify or characterize with the available data probably limit the
منابع مشابه
WFPC2 CTE for Extended Sources: I. Photometric Correction
We measure the effects of charge transfer efficiency (CTE) losses on resolved sources in Wide Field and Planetary Camera 2 (WFPC2) images from 1995 to 2008. We compare medium and long exposures of the Hubble Deep Field – North taken with the F606W filter at several epochs against a “truth” mosaic of the field taken with the Advanced Camera for Surveys early in that instrument’s operation. We ad...
متن کاملSpectroscopic Study of Charge Transfer Complexes of Dibenzo-24-crown-8 (DB24C8) with Iodine in Three Chlorinated Solvents
Charge Transfer (CT) complexes formed between dibenzo-24-crown-8 (DB24C8) as an electron donor with the σ-electron acceptor iodine (I2) in chloroform, dichloromethane, and 1,2-dichloroethane solutions have been studied by different spectroscopic techniques at room temperature. The spectral studies of the complexes were det...
متن کاملApplication of Charge Transfer Complexation Reaction for the Spectroscopy Determination of Anticonvulsant Drug Primidone
The interaction of the perimidone drug in solution state with the σ-acceptor iodine, the aliphatic π-acceptor tetracyanoethylene (TCNE) and the aromatic π-acceptor 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) have been studied through the initial formation of ionic intermediate to charge transfer (CT) complex in methanol at room temperature. The spectral studies of the complexes were determi...
متن کاملCEPHEID DISTANCES TO SNe Ia HOST GALAXIES BASED ON A REVISED PHOTOMETRIC ZERO-POINT OF THE HST-WFPC2 AND NEW P-L RELATIONS AND METALLICITY CORRECTIONS
With this paper we continue the preparation for a forthcoming summary report of our experiment with the Hubble Space Telescope (HST) to determine the Hubble constant using type Ia supernovae as standard candles. Two problems are addressed. (1) We examine the need for, and determine the value of, the corrections to the apparent magnitudes of our program Cepheids in the eleven previous calibratio...
متن کاملInvestigating the Inefficiency Causes of Educational Institution in the Field of Knowledge Transfer
Purpose: The purpose of this study is to determine the causes of inefficiency of educational institutions in the field of knowledge transfer. The type of research is applied in terms of purpose and the research method is qualitatively analytical. Methodology: The study population in this study is the Iranian society and is composed of groups of students, teachers, administrators, education pro...
متن کامل