Full-color direct visualization of the atrial septum to guide transseptal puncture.
نویسندگان
چکیده
INTRODUCTION Transseptal puncture is required for many interventional procedures but has a serious complication rate of approximately 1%-primarily related to misidentification of the fossa ovalis resulting in inadvertent puncture of other cardiac structures. We investigated the utility of a full color visualization catheter to correctly position and guide transseptal puncture of the fossa ovalis. METHODS AND RESULTS Transseptal puncture and left atrial cannulation were performed after visualization of the atrial septum and fossa ovalis with the visualization catheter (IRIS, Voyage Medical Inc.) on six swine. For each animal, the transseptal puncture was performed twice and the catheter was examined for clot after each puncture. The 12 transseptal punctures required 6.8 +/- 3.6 minutes procedural time and 300 +/- 94 mL of fluid administered per procedure (i.e., two punctures). IRIS visualization of the atrial septum correlated well with postmortem examination of the atrial septum. In the three animals in which a patent foramen ovale was present (as confirmed by pathological examination), it was also correctly identified by in vivo visualization using the IRIS catheter. CONCLUSION The IRIS catheter allows direct in vivo visualization of the interatrial septum to guide transseptal puncture of previous punctures.
منابع مشابه
A transseptal puncture hazard that was close!
Introduction The possible complications of transseptal puncture occur in approximately 1% of procedures. In the electrophysiology setting, increased pericardial effusion or tamponade risk is associated with left-sided arrhythmia ablations. Reported complications relate to aortic puncture or left/right atrial free wall perforation. There is much anatomical variation in the intra-atrial septum an...
متن کاملA practical guide for building a highway between atria during transseptal puncture without radiation
OBJECTIVE To investigate whether switching the ablation catheter between the right and left atria through transseptal puncture site can be accurately performed without fluoroscopy. METHODS Forty patients with persistent atrial fibrillation (mean age, 60.2±7.4 years; 65% males) got "2C3L" approach were randomized in a 1:1 ratio to undergo either crossing interatrial septum guided by fluoroscop...
متن کاملEco-X Ray Fusion for Transseptal Puncture.
In recent years, percutaneous procedures have been used increasingly to correct structural heart disease. Many of these procedures require transseptal puncture to access the left heart chambers, although complications such as cardiac tamponade and aortic perforation may occur. In certain situations, puncture of the atrial septum is required (for placement of a MitraClip device or closure of the...
متن کاملDifferent transseptal puncture for different procedures: Optimization of left atrial catheterization guided by transesophageal echocardiography
BACKGROUND Left atrial catheterization through transseptal puncture is frequently performed in cardiac catheterization procedures. Appropriate transseptal puncture is critical to achieve procedural success. AIMS The aim of the study is to evaluate the feasibility of selective transseptal punctures, using a modified radiofrequency (RF) transseptal needle and transesophageal echocardiography (T...
متن کاملA Proposed Maneuver to Guide Transseptal Puncture Using Real-Time Three-Dimensional Transesophageal Echocardiography: Pilot Study
Aim of Study. To assess the feasibility of a new proposed maneuver "RATLe-90" using real-time three-dimensional transesophageal echocardiography (RT-3DTEE) for anatomically oriented visualization of the interatrial septum (IAS) in guiding the transseptal puncture TSP. Methods. The study included 20 patients (mean age, 60.2 ± 6.7 years; 60% males) who underwent TSP for different indications. RT-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cardiovascular electrophysiology
دوره 19 12 شماره
صفحات -
تاریخ انتشار 2008