Endothelial keratoplasty: case selection in the learning curve.
نویسندگان
چکیده
PURPOSE Many corneal surgeons are making the transition from penetrating keratoplasty to endothelial keratoplasty techniques such as Descemet's stripping endothelial keratoplasty and Descemet's stripping automated endothelial keratoplasty in the routine treatment of corneal endothelial failure. Donor dislocation is the commonest complication of these newer techniques. We set out to determine whether preoperative lens/iris diaphragm integrity might influence the rate of donor dislocation and whether donor endothelial failure was more common after surgical intervention for donor dislocation. DESIGN A retrospective multisurgeon comparative case series from a large teaching and referral center. PARTICIPANTS Ninety-three eyes of 85 patients: consecutive cases of Descemet's stripping endothelial keratoplasty (n = 77) or Descemet's stripping automated endothelial keratoplasty (n = 16) performed between March 2004 and January 2007. METHODS A retrospective review of case notes. MAIN OUTCOME MEASURES The number of eyes with an open communication between the anterior and posterior chambers (an iridectomy or lens capsular defect not covered by a posterior chamber intraocular lens), the number of eyes requiring surgical intervention to correct donor dislocation, and the number of eyes with donor endothelial failure within the follow-up period. RESULTS Complete data sets were available for analysis in 89 eyes. The median follow-up interval at the time of the audit was 7 months (range 1-34 months). Donor dislocation was significantly more common (P = 0.017) in eyes with an open communication between the anterior and posterior chambers, occurring in 11 of 25 cases (44%) versus 12 of 64 cases (19%) with an intact iris/lens diaphragm. Early endothelial failure was significantly more common (P = 0.011) in cases requiring additional surgical intervention for donor dislocation, occurring in 6 of 21 cases (29%) after successful surgical reattachment of a dislocated donor disc versus 4 of 67 cases (6%) in which no additional intervention was required. CONCLUSIONS Donor dislocation after endothelial keratoplasty is more common in cases with an open communication between the anterior and posterior chambers. The risk of donor endothelial failure is increased in cases of donor dislocation. Trainee surgeons and surgeons in making the transition from penetrating keratoplasty should initially select cases with an intact lens/iris diaphragm.
منابع مشابه
Clinical Outcomes of Descemet Membrane Endothelial Keratoplasty During the Surgeon Learning Curve Versus Descemet Stripping Endothelial Keratoplasty Performed at the Same Time
PURPOSE To compare outcomes after Descemet Membrane Endothelial Keratoplasty (DMEK) and traditional Descemet Stripping Endothelial Keratoplasty (DSEK) during the surgeon's DMEK learning curve in a prospective, non-randomized, consecutive, interventional case series. METHODS Consecutive patients presenting to the university eye clinics and undergoing endothelial keratoplasty were included. Dat...
متن کامل[Complications after endothelial keratoplasty: three years of experience].
OBJECTIVE To study the complications after Descemet's stripping automated endothelial keratoplasty (DSAEK). METHODS Retrospective study of 75 eyes in 67 patients with Fuchs' endothelial dystrophy or bullous keratopathy operated on in the Instituto de Oftalmología La Arruzafa from March, 2007 until March, 2010. Phacoemulsification and IOL implantation was involved in 30 cases. All surgical and...
متن کاملMulticenter study of descemet membrane endothelial keratoplasty: first case series of 18 surgeons.
IMPORTANCE Surgeons starting to perform Descemet membrane endothelial keratoplasty (DMEK) should be informed about the learning curve and experience of others. OBJECTIVE To document the clinical outcome of standardized "no-touch" DMEK and its complications during the learning curves of experienced surgeons. DESIGN, SETTING, AND PARTICIPANTS Retrospective multicenter study. A total of 431 ey...
متن کاملEfficacy of descemet membrane endothelial keratoplasty: clinical outcome of 200 consecutive cases after a learning curve of 25 cases.
OBJECTIVE To evaluate Descemet membrane endothelial keratoplasty for management of corneal endothelial disorders. METHODS Descemet membrane endothelial keratoplasty was performed in 200 patients with Fuchs endothelial dystrophy or bullous keratopathy. Best-corrected visual acuity, subjective and objective refractive outcome and stability, and endothelial cell density were evaluated at 1, 3, a...
متن کاملEfficacy and safety of Descemet’s membrane endothelial keratoplasty versus Descemet’s stripping endothelial keratoplasty: A systematic review and meta-analysis
PURPOSE Based on current evidence, the efficiency and safety of Descemet's membrane endothelial keratoplasty (DMEK) was compared with that of Descemet's stripping endothelial keratoplasty (DSEK). METHODS Pubmed, Embase, Web of Science, the Cochrane Database and conference abstracts were comprehensively searched for studies that compared the efficacy and safety of DMEK and DSEK. The efficacy o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cornea
دوره 27 10 شماره
صفحات -
تاریخ انتشار 2008