An in-phantom dosimetry system using pin silicon photodiode radiation sensors for measuring organ doses in x-ray CT and other diagnostic radiology.
نویسندگان
چکیده
A dosimetry system using commercially available pin silicon photodiodes as the sensor is evaluated for in-phantom dose measurements in x-ray CT and other diagnostic radiology. System sensitivity measured as a function of the effective energy of x rays was between 0.37 and 0.49 V/mGy at an effective energy range between 23.5 and 72 keV. The minimum detectable organ dose with 25% uncertainty was estimated to be 0.02 mGy. The excellent output linearity was found over a dose range from 0.03 to more than 10 mGy with flat dose rate response of system sensitivity up to 35 mGy s(-1), though the sensitivity indicated some energy dependence across the diagnostic energy range with a maximum of about 10%/10 keV. Since angular dependence of the sensitivity of the photodiode sensor was found to be small enough it would induce negligible dose error. Dose profile measurement along the axis of a thoracic phantom undergoing CT chest examination indicated the reliability of dose values over a range of two orders of magnitude from less than 0.2 to 12 mGy. The present dosimetry system having advantages of high sensitivity with immediate readout of dose values, low cost, and easy construction would widely be used as an alternative to TLD dosimeters for organ and skin dose measurements in CT and other diagnostic radiology.
منابع مشابه
Organ dose measurement in x-ray CT and other diagnostic radiology by using novel photodiode dosimeters installed in an anthropomorphic phantom
Dosimetry system for measuring organ doses of the patients undergoing clinical x-ray examinations was devised by using newly developed photodiode dosimeters installed in an anthropomorphic phantom realizing standard Japanese adult body. The system was constructed using pin silicon photodiode dosimeters, 32 and extra two in number, inserted at the positions of tissues or organs assigned in the I...
متن کاملامکان سنجی بکارگیری عناصر نیمه هادی از نوع PIN به منظور دزیمتری پرتوهای ایکس تشخیصی
Knowing patient exact dose during radiological activities is considered as one of the main principles to decrease radiation-induced dangers which are not really necessary and affect a great deal of people. In this respect, in recent years many extensive studies have been done on types of photodiodes and production of X-ray detectors using semiconductor elements. Since these elements are not ver...
متن کاملEvaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013
Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...
متن کاملOrgan and effective dose arising from conventional diagnostic X-ray examinations by Monte Carlo simulation (MCNP-4C Code)
ABSTRACTBackground: Monte Carlo simulation has been used by many researchers to calculate organ and effective dose of patients arising from conventional X-ray examinations. In this study the radiation transport code, MCNP-4C, has been used to perform Monte Carlo simulations to estimate radiation dose delivered to different organs in conventional X-ray examinations.Material and Methods: In this...
متن کاملComparison of the current of UV ray radiation on PIN Silicon photodiode and Gallium Arsenide
The high-energy UV ray radiation on PIN Silicon photodiodes reduces the optimal parameters of these photodiodes. In this paper, by representing a model, we compare the effect of UV dose on the bright current in these two types of photodiodes and confirm the analytic relationships in order to simulate a model with the help of the Silvaco- Atlas software. In this model, Silicon photodiodes and Ga...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 29 7 شماره
صفحات -
تاریخ انتشار 2002