Marginal microleakage of cervical composite resin restorations bonded using etch-and-rinse and self-etch adhesives: two dimensional vs. three dimensional methods

نویسندگان

  • Maryam Khoroushi
  • Ailin Ehteshami
چکیده

OBJECTIVES This study was evaluated the marginal microleakage of two different adhesive systems before and after aging with two different dye penetration techniques. MATERIALS AND METHODS Class V cavities were prepared on the buccal and lingual surfaces of 48 human molars. Clearfil SE Bond and Single Bond (self-etching and etch-and-rinse systems, respectively) were applied, each to half of the prepared cavities, which were restored with composite resin. Half of the specimens in each group underwent 10,000 cycles of thermocycling. Microleakage was evaluated using two dimensional (2D) and three dimensional (3D) dye penetration techniques separately for each half of each specimen. Data were analyzed with SPSS 11.5 (SPSS Inc.), using the Kruskal-Wallis and Mann-Whitney U tests (α = 0.05). RESULTS The difference between the 2D and 3D microleakage evaluation techniques was significant at the occlusal margins of Single bond groups (p = 0.002). The differences between 2D and 3D microleakage evaluation techniques were significant at both the occlusal and cervical margins of Clearfil SE Bond groups (p = 0.017 and p = 0.002, respectively). The difference between the 2D and 3D techniques was significant at the occlusal margins of non-aged groups (p = 0.003). The difference between these two techniques was significant at the occlusal margins of the aged groups (p = 0.001). The Mann-Whitney test showed significant differences between the two techniques only at the occlusal margins in all specimens. CONCLUSIONS Under the limitations of the present study, it can be concluded that the 3D technique has the capacity to detect occlusal microleakage more precisely than the 2D technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microleakage comparison of three types of adhesive systems versus GIC-based adhesive in class V composite restorations

Background and aims: New dentin bonding agents and techniques have been developed to reduce microleakage and create higher bond strength. This in-vitro study compared the microleakage of three resin-based adhesives versus a GIC-based adhesive on class V composite restorations.  Materials and Methods: Class V cavities were prepared on the buccal surfaces of 72 sound premolars, randomly assigned ...

متن کامل

Effect of Postoperative Bleaching on Microleakage of Etch-and-Rinse and Self-etch Adhesives

BACKGROUND Bleaching the discoloured teeth may affect the tooth/composite interface. The aim of this in vitro experimental study was to evaluate the effect of vital tooth bleaching on microleakage of existent class V composite resin restorations bonded with three dental bonding agents. METHODS Class V cavities were prepared on buccal surfaces of 72 intact, extracted human anterior teeth with ...

متن کامل

An In Vitro Evaluation of Leakage of Two Etch and Rinse and Two Self-Etch Adhesives after Thermocycling

Our experiment evaluated the microleakage in resin composite restorations bonded to dental tissues with different adhesive systems. 40 class V cavities were prepared on the facial and lingual surfaces of each tooth with coronal margins in enamel and apical margins in cementum (root dentin). The teeth were restored with Z100 resin composite bonded with different adhesive systems: Scotchbond Mult...

متن کامل

Microleakage comparison of three types of adhesive systems versus GIC-based adhesive in class V composite restorations

Background and aims: New dentin bonding agents and techniques have been developed to reduce microleakage and create higher bond strength. This invitro study compared the microleakage of three resinbased adhesives versus a GIC-based adhesive on class V composite restorations. Materials and Methods: Class V cavities were prepared on the buccal surfaces of 72 sound premolars, randomly assigned to ...

متن کامل

Effects of Three Hemostatic Agents on Microleakage of Cervical Composite Resin Restorations Bonded to Simulated Caries-Affected Tooth Substrate Using One-Step Self-Etch Adhesive

Background and Aim: This study aimed to evaluate the microleakage of cervical res-torations with the use of a one-step self-etch adhesive after application of three differ-ent hemostatic agents. Materials and Methods: In this in vitro study, 96 cervical cavities were prepared on 24 intact and 24 demineralized teeth. Forty-eight class V cavities with sound tooth substrate were assigned to group...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 41  شماره 

صفحات  -

تاریخ انتشار 2016