Evaluation of S-values and dose distributions for (90)Y, (131)I, (166)Ho, and (188)Re in seven lobes of the rat liver.
نویسندگان
چکیده
PURPOSE Rats have been widely used in radionuclide therapy research for the treatment of hepatocellular carcinoma (HCC). This has created the need to assess rat liver absorbed radiation dose. In most dose estimation studies, the rat liver is considered as a homogeneous integrated target organ with a tissue composition assumed to be similar to that of human liver tissue. However, the rat liver is composed of several lobes having different anatomical and chemical characteristics. To assess the overall impact on rat liver dose calculation, the authors use a new voxel-based rat model with identified suborgan regions of the liver. METHODS The liver in the original cryosectional color images was manually segmented into seven individual lobes and subsequently integrated into a voxel-based computational rat model. Photon and electron particle transport was simulated using the MCNPX Monte Carlo code to calculate absorbed fractions and S-values for (90)Y, (131)I, (166)Ho, and (188)Re for the seven liver lobes. The effect of chemical composition on organ-specific absorbed dose was investigated by changing the chemical composition of the voxel filling liver material. Radionuclide-specific absorbed doses at the voxel level were further assessed for a small spherical hepatic tumor. RESULTS The self-absorbed dose for different liver lobes varied depending on their respective masses. A maximum difference of 3.5% was observed for the liver self-absorbed fraction between rat and human tissues for photon energies below 100 keV. (166)Ho and (188)Re produce a uniformly distributed high dose in the tumor and relatively low absorbed dose for surrounding tissues. CONCLUSIONS The authors evaluated rat liver radiation doses from various radionuclides used in HCC treatments using a realistic computational rat model. This work contributes to a better understanding of all aspects influencing radiation transport in organ-specific radiation dose evaluation for preclinical therapy studies, from tissue composition to organ morphology and activity distribution.
منابع مشابه
A Strategy to Reduce Red Marrow Dose for Intraperitoneal Radioimmunotherapy I
The aim of this study was to determine whether shorter-lived radionuclides can reduce red marrow (RM) toxicity for i.p. radioimmunotherapy (RIT). The potential radionuclides, which included Lu-177, 1-131, Y-90, Re-186, Re-188, and Ho-166, were attached to antibody CC49. Each radiopharmaceutical was assumed to have identical in vivo pharmacokinetics. Blood and whole body retention data acquired ...
متن کاملA strategy to reduce red marrow dose for intraperitoneal radioimmunotherapy.
The aim of this study was to determine whether shorter-lived radionuclides can reduce red marrow (RM) toxicity for i.p. radioimmunotherapy (RIT). The potential radionuclides, which included Lu-177, I-131, Y-90, Re-186, Re-188, and Ho-166, were attached to antibody CC49. Each radiopharmaceutical was assumed to have identical in vivo pharmacokinetics. Blood and whole body retention data acquired ...
متن کاملDosimetric analysis for the selection of radionuclides in bone pain palliation targeted therapy: A Monte Carlo simulation
Introduction:The use of beta emitters is one of the effective methods for palliation of bone metastasis. The risk of normal tissue toxicity should be evaluated in the bone pain palliation treatment. Methods: In this study, the Monte Carlo simulation code MCNPX was used for simulation a bone phantom model consisted of bone marrow, bone and soft tissue. Spe...
متن کاملStudying the Effect of Kidney Internal Structure on Beta Absorbed Dose of Radiopharmaceuticals Hg-203, Ho-166 And Y-90 Using Monte Carlo
Large quantities of radiopharmaceuticals prescribed for treatment and diagnosis are excreted through kidney. Therefore, radiation unwanted dose is created in kidney. As a result, exact calculation of prescribed radiopharmaceuticals amount is important. Monte Carlo method is used for simulation of radiation transport in body due to random nature of radiation. In this research, for the first time...
متن کاملStudying the Effect of Kidney Internal Structure on Beta Absorbed Dose of Radiopharmaceuticals Hg-203, Ho-166 And Y-90 Using Monte Carlo
Large quantities of radiopharmaceuticals prescribed for treatment and diagnosis are excreted through kidney. Therefore, radiation unwanted dose is created in kidney. As a result, exact calculation of prescribed radiopharmaceuticals amount is important. Monte Carlo method is used for simulation of radiation transport in body due to random nature of radiation. In this research, for the first time...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 3 شماره
صفحات -
تاریخ انتشار 2012