Determinants of quantitative optic nerve measurements using spectral domain optical coherence tomography in a population-based sample of non-glaucomatous subjects.
نویسندگان
چکیده
PURPOSE To evaluate the ocular and systemic factors influencing measurements of optic nerve head (ONH) parameters and retinal nerve fiber layer (RNFL) thickness with spectral-domain optical coherence tomography (SD-OCT) in healthy Chinese adults. METHODS Adults ranging in age from 40 to 80 years were consecutively recruited from the population-based Singapore Chinese Eye Study. A SD-OCT instrument was used to measure ONH and RNFL parameters. A total of 542 eyes from 542 non-glaucomatous Chinese subjects were analyzed. Univariable and multiple linear regression analyses were performed to examine the effects of a range of ocular (e.g., intraocular pressure [IOP], axial length [AL], disc area) and systemic (e.g., blood pressure, serum glucose) factors on ONH and RNFL parameters. RESULTS In multiple regression analyses, neuroretinal rim area was independently associated with age (β = -0.006, P < 0.001), disc area (β = 0.183, P < 0.001), IOP (β = -0.009, P = 0.008), AL (β = -0.023, P = 0.004), and lens nuclear color (β = 0.042, P = 0.001). Vertical cup-to-disc ratio was independently correlated with age (β = 0.003, P < 0.001), disc area (β = 0.207, P < 0.001), IOP (β = 0.004, P = 0.014), AL (β = 0.010, P = 0.008), and lens nuclear color (β = -0.017, P = 0.006). Average RNFL thickness was independently related to age (β = -0.204, P = 0.001), disc area (β = 4.218, P < 0.001), signal strength (β = 1.348, P < 0.001), and AL (β = -1.332, P < 0.001). Disc area had the strongest effect on measurements of ONH parameters and RNFL thickness. CONCLUSIONS In a non-glaucomatous population, optic nerve measurements with SD-OCT vary with disc area, age, IOP, AL, lens nuclear color, and signal strength, but systemic parameters have little influence. This information may be useful for interpretation of SD-OCT measurements.
منابع مشابه
Clinical Applications of Optical Coherence Tomography in Ophthalmology
Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases. Furtherm...
متن کاملRetinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography
Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...
متن کاملبررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک
Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...
متن کاملComparison of optic nerve head parameter measurements obtained by time-domain and spectral-domain optical coherence tomography.
PURPOSE To compare the measurements of the optic nerve head (ONH) parameters provided by time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT). METHODS Four ONH parameters were analyzed: optic disc area, rim area, cup-to-disc area ratio (CDR), and vertical cup-to-disc ratio (VCDR). Stratus OCT and Cirrus HD-OCT were used to obtain measurements by TD-OCT and SD-OCT, resp...
متن کاملLocalized Retinal Nerve Fiber Layer Defects Detected by Optical Coherence Tomography: The Beijing Eye Study
OBJECTIVE To assess the prevalence of localized retinal nerve fiber layer defects (LRNFLD) and associated factors in adult Chinese. METHODS The population-based Beijing Eye Study 2011 included 3468 individuals (mean age: 64.6±9.8 years (range: 50-93 years)). The study participants underwent a detailed ophthalmological examination including spectral-domain optical coherence tomography (Spectra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 52 13 شماره
صفحات -