Use of continuous infusion pumps during radiation treatment.
نویسندگان
چکیده
INTRODUCTION Despite increasing chemoradiotherapy treatment, there is a paucity of information regarding the effects of radiation exposure on ambulatory infusion pumps used to deliver chemotherapy or other essential medications. The aim of this overview is to present the available evidence on this subject, heighten awareness within the clinical community, provide considerations for minimizing possible negative effects on patient care, and encourage the monitoring of infusion devices after exposure to radiation or electromagnetic interference. METHODS Published literature was systematically searched using MEDLINE and EMBASE; gray literature was searched using Google and an environmental scan of relevant Web sites. A multidisciplinary working group reviewed the compiled evidence, and a draft of the document was sent to health professionals from various disciplines for an external review. RESULTS Four reports and three manufacturer device alerts were identified that suggest a risk of pump malfunction as a result of radiation exposure. The estimated cumulative dose at which pump failure has been reported ranges from 28.5 to 42 Gy; however, additional clinical investigations should be undertaken. Pump relocation, pump shielding, and assessment of the pump after radiation exposure are most commonly suggested to minimize pump malfunction related to radiation exposure. A list of additional considerations is offered for those developing institution specific policies and procedures based on the available evidence and expert consensus. CONCLUSION The varied and unpredictable results of radiation exposure on infusion devices suggest that additional testing should be carried out to determine the limits of dose exposure and to raise awareness around this patient safety issue.
منابع مشابه
In-Vitro Red Blood Cells Integrity and Morphology Changes after Passing Through Volumetric Peristaltic Infusion Pump
Background: It is not clear whether the use of volumetric peristaltic infusion pumps, affect the quality of the erythrocytes during packed cell transfusion or not. In the present study in vitro quality of red blood cells was assessed after using this type of infusion pumps in a prospective study. Materials and Methods: In this study 60 units of packed red cells were examined before and after p...
متن کاملProtocol for a randomised crossover trial to evaluate patient and nurse satisfaction with electronic and elastomeric portable infusion pumps for the continuous administration of antibiotic therapy in the home: the Comparing Home Infusion Devices (CHID) study
INTRODUCTION Previous studies comparing satisfaction with electronic and elastomeric infusion pumps are limited, and improvements in size and usability of electronic pumps have since occurred. The Comparing Home Infusion Devices (CHID) study plans to assess patient and nurse satisfaction with an elastomeric and electronic pump for delivering intravenous antibiotic treatment in the home. Seconda...
متن کاملAn Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital
Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...
متن کاملAn Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital
Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...
متن کاملSimultaneous use of two external subcutaneous pumps delivering insulin and SYMLIN: use of a double-pump system.
Corresponding Author: Alan B. Schorr, D.O., 380 Middletown Boulevard, Suite 710, Langhorne, PA 19047; email address [email protected] The combination of insulin and an amylin mimetic is an option for diabetes treatment.1,2 The effectiveness of this modality has been established, but there is a limited amount of literature regarding the use of this combined treatment via continuous subcutaneo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of oncology practice
دوره 9 2 شماره
صفحات -
تاریخ انتشار 2013