The uncemented isoelastic/isotitan total hip arthroplasty. A 10-15 years follow-up with bone mineral density evaluation.

نویسندگان

  • Onkar N Nagi
  • Senthil Kumar
  • Sameer Aggarwal
چکیده

The present study analyses the long-term outcome of isoelastic hip prostheses and their influence on the extent of periprosthetic bone remodeling. Ninety-two patients (102 hips) with Isoelastic/Isotitan uncemented total hip arthroplasty were evaluated after an average of 13.4 years. The average age of patients at surgery was 42.5 years. The clinical outcome was assessed based on the Harris hip score, complications and thigh pain. Bone mineral density (BMD) of the proximal femur in the seven Gruen zones was evaluated by dual-energy X-ray absorptiometry (DEXA) scans with the contralateral hip serving as a control. The average Harris hip score at the most recent follow-up was 72 points, with 72 hips (70%) rating completely pain free. Eight stems required revision whereas none of the cups showed any evidence of loosening. The change in the mean BMD values between the femora on the operated side and the contralateral femora averaged 15% for all zones Although the isoelastic stems are no longer used owing to their high loosening rate, it appears that this prosthesis preserved periprosthetic bone better than reported for cemented or uncemented metallic implants. Besides, the provision of a titanium coating on the isoelastic stem, comparable to that on the RM cup, would presumably have improved its long-term fixation by encouraging bony ongrowth.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bone density study of the proximal femur after hip arthroplasty with porous-coated implants

Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...

متن کامل

Effects of postoperative weight-bearing on body composition and bone mineral density after uncemented total hip arthroplasty.

OBJECTIVE To investigate whether a postoperative weight-bearing regimen affects changes in bone mineral density and body composition after uncemented total hip arthroplasty, and to investigate the changes over a 5-year period after the surgical procedure. DESIGN Secondary analysis of a previous randomized controlled trial. METHODS A total of 39 patients were randomized to immediate full wei...

متن کامل

A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems

BACKGROUND AND PURPOSE Plasma-sprayed hydroxyapatite (HA) is a successful coating for fixation of uncemented femoral stems. There may be alternative coatings with advantages in bone remodeling and transport of bone-active substances. We investigated whether an electrochemically deposited hydroxyapatite, Bonemaster (BM), might be a safe alternative in total hip arthroplasty. Our hypothesis was t...

متن کامل

Periprosthetic bone mineral density and fixation of the uncemented CLS stem related to different weight bearing regimes

BACKGROUND AND PURPOSE There is no consensus on the best rehabilitation regime after uncemented total hip arthroplasty. Theoretically, bone ingrowth into the implant should benefit from initial partial weight bearing. We investigated whether the degree of postoperative weight bearing influences the periprosthetic bone mineral density (BMD) and/or the stability of the CLS stem. PATIENTS AND ME...

متن کامل

Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density

BACKGROUND AND PURPOSE Low bone mineral density (BMD) may jeopardize the initial component stability and delay osseointegration of uncemented acetabular cups in total hip arthroplasty (THA). We measured the migration of uncemented cups in women with low or normal BMD. PATIENTS AND METHODS We used radiostereometric analysis (RSA) to measure the migration of hydroxyapatite-coated titanium alloy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 72 1  شماره 

صفحات  -

تاریخ انتشار 2006