The artificial disc is a mobile implant for degenerative disc replacement that attempts to lessen the degeneration of the adjacent elements. However, inconsistent biomechanical results for the neighboring elements have been reported in a number of studies. The present study used finite element (FE) analysis to explore the biomechanical differences at the surgical and both adjacent levels following artificial disc replacement and interbody fusion procedures. First, a three-dimensional FE model of a five-level lumbar spine was established by the commercially available medical imaging software Amira 3.1.1, and FE software ANSYS 9.0. After validating the five-level intact (INT) model with previous in vitro studies, the L3/L4 level of the INT model was modified to either insert an artificial disc (ProDisc II; ADR) or incorporate bilateral posterior lumbar interbody fusion (PLIF) cages with a pedicle screw fixation system. All models were constrained at the bottom of the L5 vertebra and subjected to 150N preload and 10Nm moments under four physiological motions. The ADR model demonstrated higher range of motion (ROM), annulus stress, and facet contact pressure at the surgical level compared to the non-modified INT model. At both adjacent levels, ROM and annulus stress were similar to that of the INT model and varied less than 7%. In addition, the greatest displacement of posterior annulus occurred at the superior-lateral region. Conversely, the PLIF model showed less ROM, less annulus stress, and no facet contact pressure at the surgical level compared to the INT model. The adjacent levels had obviously high ROM, annulus stress, and facet contact pressure, especially at the adjacent L2/3 level. In conclusion, the artificial disc replacement revealed no adjacent-level instability. However, instability was found at the surgical level, which might accelerate degeneration at the highly stressed annulus and facet joint. In contrast to disc replacement results, the posterior interbody fusion procedure revealed possibly accelerative degeneration of the annulus and facet joint at both adjacent levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cervical and lumbar spinal arthroplasty: clinical review.

In contrast to cervical and lumbar fusion procedures, the principal aim of disk arthroplasty is to recapitulate the normal kinematics and biomechanics of the spinal segment affected. Following decompression of the neural elements, disk arthroplasty allows restoration of disk height and maintenance of spinal alignment. Based on clinical observations and biomechanical testing, the anticipated adv...

متن کامل

Effect of Stress on Intervertebral Disc and Facet Joint of Novel Lumbar Spine Soft Implant: Biomechanical Analysis

This study was to evaluate the effect of stress on the intervertebral disc and facet joint after implantation of device for intervertebral assisted motion (DIAM). Nine fresh human lumbar (L1-L5) cadavers were studied. The stress on L3-4, adjacent intervertebral disc and facet joints was measured in four groups. The cadavers in Group 1 were measured without special treatment; the lumbar discecto...

متن کامل

The Anterior Retroperitoneal Approach to the Degenerative Lumbar Spine: Clinico-Therapeutic Remarks

The anterior approach is a well-known surgical technique for the treatment of degenerative diseases of the lumbar spine. Through this approach is possible to perform arthrodesis, arthroplasty, discectomy, corpectomy to treat a lot of degenerative conditions. The ALIF procedure is one of the most widely used technique, and is argued to have biomechanical advantages over posterior approaches for ...

متن کامل

Biomechanical Changes in Disc Pressure and Facet Strain after Lumbar Spinal Arthroplasty with CharitéTM in the Human Cadaveric Spine under Physiologic Compressive Follower Preload.

AIM Arthroplasty maintains the biomechanical features of a healthy disc, decreases the adjacent segment disease rate, and decreases the accelerated degeneration rate of the neighboring discs in traditional fusion procedures. However, there are only a few reports on adjacent disc pressure (DP) and facet strain (FS) after lumbar arthroplasty under a physiologic compressive preload. MATERIAL AND...

متن کامل

Hybrid Surgery: Fusion and Disc Arthroplasty is Superior To Two Disc Arthroplasties in the Lumbar Spine. Randomized Controlled Trial

STuDY DeSign: Prospective study. ObJeCTive: To study the validity of Hybrid construction (Anterior Lumbar Interbody Fusion) ALIF at one level and (Total Disc Arthroplasty) TDA at the adjacent level for two levels disc disease in the lumbar spine as an alternative surgical strategy compared to two levels disc arthroplasties. SuMMARY OF bACkgROunD DATA: With growing evidence that fusion construct...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical engineering & physics

دوره 31 2  شماره 

صفحات  -

تاریخ انتشار 2009