Preclinical Evaluation of an MR-EP Suite including an MR-EP Navigator and Dedicated MR-EP Catheters

نویسندگان

  • S. Krueger
  • R. Holthuizen
  • J. Smink
  • S. Weiss
  • O. Lips
  • B. David
  • D. Wirtz
  • S. F. Pedersen
  • D. Caulfield
  • J. Bostock
  • G. Gao
  • P. Chinchapatnam
چکیده

Introduction: Cardiac arrhythmias, e.g. atrial fibrillation and ventricular tachycardia, are increasingly treated by electrophysiological (EP) interventions [1]. Applying MR for guiding these interventions offers advantages like 3D visualization of the cardiac soft tissue in relation to the catheter, visualization of the treatment effect and absence of ionizing radiation [2,3]. The step towards clinical MR-guided EP interventions requires a focus on RF safety of the devices, localization accuracy of the catheters, guidance of the procedure, intra-cardiac signal quality and procedure workflow. Here, an MR-EP suite based on an MR-EP Navigator application with a realtime interface to the MR system and therapy equipment is demonstrated along with specialized MR-EP catheters. These catheters are based on RF-safe concepts for both, MRand EP functionality [4,5]. RF-safety, localization accuracy and EP signal quality of these devices are demonstrated in vivo. The operation of the MR-EP suite and the workflow of the MR-EP Navigator are demonstrated in pre-clinical MR-guided EP experiments. Materials and Methods: All experiments were performed on a clinical wholebody 1.5T MR scanner (Achieva I/T, Philips Healthcare, Netherlands) equipped with an in-room display. 7F MR-EP catheters with ring electrodes and a tracking coil were used in 12 pigs. The RA and RV were catheterized via venous access. Intra-cardiac and tracking signals were transferred via high resistance wires (HRW) and a transformer-based transmission line to increase RF safety [4,5], respectively. Intra-cardiac signal quality, tracking accuracy and RF-safety were assessed in vivo. 3D b-FFE soft tissue images and 3D CE-MRA angiograms were acquired prior to the catheterization of the pigs to serve as roadmaps. The MR-EP Navigator was linked to the host computer of the MR system and to the EP equipment (EP Tracer, CardioTek, The Netherlands) via fiber-optic ethernet. The MR-EP Navigator visualizes MR real-time 2D-images and tracking positions or 3D images (roadmaps) as well as real-time EP-data from the EP-recorder and serves as the main control point for the procedure. Surface renderings of the e.g. atrium and other relevant structures can be displayed together with reformatted 2D slices at the catheter position, which can be angulated freely or using the geometries from the planned scans. Real-time MR images can be added to the 3D scene according to their imaging geometry. The MR-EP Navigator allows for automatic segmentation of the left atrium on human MR data-sets (Fig.1 top) [6]. The real-time MR-system interface moreover provides means for the interactive control of the scanner by the MR-EP Navigator and for receiving of data (besides images and tracking data e.g. metadata, raw data or physiology data). EP data are transferred between the EP equipment and the MR-EP Navigator in real-time. The MR-EP Navigator provides a method for on-the-fly manual evaluation of the intra-cardiac signals and produces updated interpolated colormaps, when new data become available. The MR-EP Navigator is based on a rapid prototyping platform that allows a flexible combination of the visualization and control techniques for the MRguided EP workflow. Results: The MR-EP suite allowed performing EP interventions very efficiently and accurately under MR-guidance. The in vivo tracking jitter with the catheter resting in the vena cava was 0.49mm. This jitter includes some residual physiologic motion. Due to the excellent guidance achieved by combining high resolution 3D soft tissue images with angiograms, real-time images and accurate tracking, fast mapping of e.g. 40 points in RV in 20min was typically possible. The in-bore intra-cardiac recordings using HRW [5] were of excellent quality (Fig. 1, center), and artifacts induced by real-time MRI were acceptable even without additional filtering (Fig. 1, bottom). Thus, real-time imaging-guided mapping of the heart is possible with this set-up. However, in order to resolve smaller EP-signals, e.g. from the His bundle, and to simplify in-room communication, scanner operation was halted during acquisition of a data point for storage in the database. The MR-EP Navigator supports the quick evaluation of activation times with an accuracy of 1ms and updates time and voltage maps on-the-fly. Atrial and ventricular pacing was achieved via the MR-EP catheters. Successful stimulation was confirmed by recording with a second MR-EP catheter and in the surface ECG. In vivo safety testing of the MR-EP catheters showed a maximum temperature increase of 0.7K after 10min of 4W/kg global SAR (expected heating without device 0.6K). Thus, device related heating is extremely low and almost non-measurable. Conclusion: The experimental setup of the MR-EP suite and the MR-EP Navigator application provided excellent guidance and an efficient workflow for MR-guided EP interventions. The MR-EP devices based on RF-safety technology described in [4,5] showed very good localization accuracy and intracardiac signal quality in vivo, while device-related RF-heating was not observed. The presented MR-EP suite is, therefore, suitable for initial clinical MRguided EP interventions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RF-safe, multi-polar, diagnostic MR-EP Catheter employing resistive Leads and a Transformer-based Transmission Line

Objective The use of MRI for guidance of cardiac electrophysiology (EP) procedures is gaining attention, because MRI avoids X-ray dose, allows the visualization of the catheter in relation to the myocard, the assessment of cardiac function and ablation monitoring. MR-EP procedures have been demonstrated in animals [1], but the safety of MR-EP catheters still has to be addressed [2]. While RF-sa...

متن کامل

P-167: Risk Factors for Ectopic Pregnancy: A Case-Control Study

Background: Ectopic pregnancy (EP) is a common condition which presents a major health problem for women of childbearing age. This study aims to analyze and identify risk factors that have the potential for EP and evaluating the contribution of the risk factors associated EP. Materials and Methods: In this case control study, performed from 2006 to 2011 at Arash hospital, the casepatients were ...

متن کامل

Current Rates of Publication for Podium and Poster Presentations at the American Society for Surgery of the Hand Annual Meetings

Background:  Research projects are presented at the Annual Meetings of the American Society for Surgery of the Hand (ASSH). It is unknown how many achieve publication in peer-reviewed journals. We sought to determine current rates of publication of podium and poster presentations.   Methods:  All ASSH podium and poster presentations from 2000 to 2005 were reviewed, and an Internet-based search ...

متن کامل

MR-guided cardiac radiofrequency ablation with catheter-tracked local MR lesion monitoring

Background MR-guided electrophysiology (MR-EP) for the treatment of arrhythmia has the potential advantages of improved soft tissue contrast navigation and visualization of ablation-induced tissue changes. In the past, the development of MR-conditional EP catheters and an appropriate image guidance platform have represented major obstacles. The aim of this work was to establish and evaluate a c...

متن کامل

Retroclival ecchordosis physaliphora: MR imaging and review of the literature.

BACKGROUND AND PURPOSE Ecchordosis physaliphora (EP), found in about 2% of autopsies, is a clinically inconspicuous notochordal remnant appearing at the dorsal wall of the clivus. To our knowledge, a systematic review of its MR features does not exist. The aim of this study was to describe the MR imaging findings of incidentally found retroclival EP with special respect to its differentiation f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009