Laser-Induced Fluorescence of Singly-Charged Xenon inside a 6-kW Hall Thruster
نویسندگان
چکیده
We present laser-induced fluorescence velocimetry measurements of the 5d[4]7/2 → 6p[3]5/2 transition for singly-charged xenon (Xe II) at 834.953 nm (vacuum) inside and in the near-field plume of a 6-kW Hall thruster. The thruster has a nominal operating discharge voltage of 300 V and a nominal anode mass flow rate of 20 mg/s. Axial velocity profiles are obtained along the centerline of the discharge channel. The thruster is operated under seven conditions spanning discharge voltages of 150-600 V and anode mass flow rates of 10-30 mg/s. The near-field results match those obtained in a previous experiment on the same thruster, validating the new optical fiber setup. The lengths of the acceleration zone are found to vary from 14 to 26 mm. The location of the acceleration zone appears to move downstream as the flow rate increases but moves upstream as the discharge voltage increases. The signal to noise ratio varies greatly and is generally an order of magnitude lower at locations believed to be inside the Hall current. At these locations, the widths of the velocity distributions are several times wider than those found elsewhere and the distributions are often bimodal. This phenomenon is likely to be the result of taking timeaveraged measurements on a highly oscillatory plasma. By deconvolving the pre-accelerated velocity distribution function from the downstream distributions, we can roughly approximate the minimum and maximum instantaneous bulk velocities found at each scan location. The plot of these velocities supports the possibility that the entire acceleration zone is oscillating back and forth in space.
منابع مشابه
Laser-Induced Fluorescence of Singly-Charged Xenon in a 6-kW Hall Thruster Plume
We present laser-induced fluorescence velocimetry measurements of the 5d[4]7/2 → 6p[3]5/2 transition for singly-charged xenon (Xe II) at 834.953 nm (vacuum) in the near-field plume of a 6-kW Hall thruster. Axial velocity profiles were obtained at six locations axially along the channel centerline and nine locations radially across the thruster channel at the exit plane. Discharge voltage was ma...
متن کاملNear-field laser-induced fluorescence velocimetry of neutral xenon in a 6-kW Hall thruster plume
We present laser-induced fluorescence (LIF) measurements of neutral xenon (6s [3/2]2) in the near-field plume of a 6-kW Hall thruster. The 823.163 nm (air) beam from a TUI Optics TA-100/830 tapered-amplifier diode laser is focused along an axial beamline onto a submillimeter interrogation volume, from which we collect resonant LIF. Polarization control via a rotating half-wave plate keeps the i...
متن کاملUsing Nonlinear Zeeman Spectroscopy to obtain In-Situ Magnetic Field Measurement in a Hall Thruster
We present the experimental results based on a novel non-intrusive method for obtaining the magnetic field magnitude profile in a 6-kW Hall thruster operating at the nominal condition. We used the Xe I 6s’[1/2]1 → 6p’[3/2]2 transition at 834.912 nm (vacuum) to perform laser-induced fluorescence spectroscopy inside the channel near the exit plane. Due to the Zeeman effect, the obtained spectra c...
متن کاملTime-Synchronized Continuous Wave Laser Induced Fluorescence Velocity Measurements of a 600 Watt Hall Thruster
A time-synchronized continuous wave laser induced fluorescence diagnostic technique based on a sample hold scheme is applied to xenon ion velocimetry of a BHT-600 Hall thruster plume. This method is capable of correlating measured fluorescence excitation lineshapes with current fluctuations in a plasma discharge and is tolerant of natural drifting in the current oscillation frequency. This pape...
متن کاملMicrosoft Word - IEPC2009-087-InternalXEI v10.docx
We present laser-induced fluorescence velocimetry measurements obtained using the Xe I 6s[3/2]2 → 6p[3/2]2 transition at 823.4 nm (vacuum) and the Xe I 6s’[1/2]1 → 6p’[3/2]2 transition at 834.9 nm (vacuum) from the inside and in the near-field plume of a 6-kW Hall thruster. The thruster is operated under seven conditions with discharge voltages ranging from 150 to 600 V, and anode mass flow rat...
متن کامل