Determination of formaldehyde in foodstuffs by flow injection spectrophotometry using phloroglucinol as chromogenic agent.
نویسندگان
چکیده
A spectrophotometric method for the determination of formaldehyde in foodstuffs was described by using phloroglucinol as the chromogenic agent. The reaction between formaldehyde and phloroglucinol could occur rapidly at room temperature under mild conditions. The spectrophotometric measurements were conducted at 474nm of an unstable intermediate orange product of the reaction, which greatly increased the sample throughput. Flow injection technique was used to control the merging and reaction timing of the reagents and sample. A detection limit (3sigma) of 0.023microg ml(-1) was achieved. The relative standard deviation was 0.29% for the determination of 7microg ml(-1) formaldehyde (n=11). The proposed method was applied to the analyses of formaldehyde in several preserved foodstuffs and the results were in good agreement with those obtained by a standard method.
منابع مشابه
Determination of formaldehyde in Brazilian alcohol fuels by flow-injection solid phase spectrophotometry.
In this work, a solid phase spectrophotometric method in association with flow injection analysis for formaldehyde determination has been developed with direct measurement of light-absorption in C(18) material. The 3,5-diacetyl-1,4-dihydrolutidine produced from the reaction between formaldehyde and fluoral P was quantitatively retained on C(18) support and the spectrophotometric detection was p...
متن کاملOn-line collection/concentration and detection of sulfur dioxide in air by flow-injection spectrophotometry coupled with a chromatomembrane cell.
A simple and rapid procedure for SO2 determination in air was developed by using a flow injection analysis (FIA) system coupled with a 3-hole chromatomembrane cell (CMC). The CMC was applied for the on-line collection/concentration of SO2 from air into a solution of 2 g l(-1) triethanolamine (TEA) solution as an absorbing solution: SO2 was converted to SO3(2-) in the alkaline absorbing solution...
متن کاملFlow Injection Spectrophotometric Determination of Sulphide by Catalytic Reduction of Toluidine Blue
Sulphide was determined spectrophotometrically at 628 nm and pH 6.7 based on its catalytic reduction of toluidine blue in the presence of Se(IV) using a flow injection system. After optimization of the measuring conditions the calibration curve was found linear up to 25 mg/mL and the detection limit was 0.3 mg/mL (30 mL injections). The ...
متن کاملUltra-trace Determination of Palladium(II) by Spectrophotometric Flow Injection Analysis
Nowadays, palladium compounds due to their especial characteristics used in different industries, mainly in electrical power sources and chemical productions as a catalyst. Therefore, Pd concentration is increasing in our around that can be contaminant our environment due its toxic effects. In this work, a simple, selective and rapid flow injection method of analysis (FIA) has been developed fo...
متن کاملDetermination of trace amounts of total arsenic in environmental samples by hydride generation flow injection-AAS using a mixed acid as a pretreatment agent.
A method is described for the determination of total arsenic by hydride generation-atomic absorption spectrophotometry using a mixed acid as a pretreatment. Hydride generation is done by the flow-injection method. The authors investigated in detail the temperature and time of decomposition using inorganic, organic arsenic and environmental standard samples, pretreated with nitric-perchloric-sul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Talanta
دوره 74 4 شماره
صفحات -
تاریخ انتشار 2008