An intra-bone axial load transducer: development and validation in an in-vitro radius model

نویسندگان

  • Nikolas K. Knowles
  • Michael Gladwell
  • Louis M. Ferreira
چکیده

BACKGROUND Accurate measurement of forces through the proximal radius can assess the effects of some surgical procedures on radioulnar load sharing, but is difficult to achieve given the redundant loading nature of the musculoskeletal system. Previously reported devices have relied on indirect measurements that may alter articular joint location and function. An axial load transducer interposed in the diaphysis of the radius may accurately quantify unknown axial loads of the proximal radius, and maintain articular location. METHODS An in-vitro radius model was developed by interposing an axial load transducer in the diaphysis of the proximal radius. Static loads of 20, 40, 60, 80, and 100 N were applied with a servo-hydraulic actuator to the native radial head at angles of 10°, 20°, 30°, and 40° in the anterior, posterior, medial and lateral directions. FINDINGS Linear regression of five repeatability trials showed excellent agreement between the transducer and applied loads (R (2) = 1 for all trials). For off-axis net joint loads, the majority of measured loading errors were within the inter-quartile range for mean loads up to 80 N. Loads below 80 N and outside the inter-quartile range had errors of less than 1 N. CONCLUSIONS The repeatability and off-axis net joint load results of this study validate the effectiveness of the interposed axial load transducer to accurately quantify proximal radius loads. The surgical technique preserves the native articular location and soft-tissue constructs, like the annular ligament. The modular design allows for testing the effects of length-changing osteotomies in subsequent biomechanical studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical Modeling of Axial Collapse of Circular Hybrid Tubes

In this paper, considering symmetric collapse mode for hybrid tubes, and using Tsai-Hill fracture criterion to take into account the off-axis strength of an orthotropic lamina, an analytical model is extended and an expression is derived for mean crushing load and fold lengths of circular hybrid tubes. In this model, the influences of the geometrical dimensions including diameter, thickness of ...

متن کامل

The axisymmetric computational study of a femoral component to analysis the effect of titanium alloy and diameter variation.

This work presents a numerical approach in order to predict the influence of implant material stiffness in a femoral component design when submitted in compression. The implant success depends on the transferred load to the neighboring bone. The finite element method can be used to analysis the stress and strain distribution in the femoral component allowing to improve the implant selection. Fo...

متن کامل

Sliding Friction Contact Stiffness Model of Involute Arc Cylindrical Gear Based on Fractal Theory

Gear’s normal contact stiffness played an important role in the mechanical equipment. In this paper, the M-B fractal model is modified and the contact surface coefficient is put forward to set up the fractal model, considering the influence of friction, which could be used to calculate accurately the involute arc cylindrical gears’ normal contact stiffness based on the fractal theory and Hertz ...

متن کامل

Embedded Crack Identification in Beam-Column Structures Under Axial Load Using an Efficient Static Data Based Indicator

A triangular model base on an investigation which has done by Sinha et al. has been developed for evaluating embedded crack localization in beam-column structures. In the assessment of this member’s behavior, the effects of displacement slope are necessary. In order to propose a crack localization method for embedded crack, an efficient static data based indicator is proposed for this crack in ...

متن کامل

Estimation of wrist fracture load using phalangeal speed of sound: an in vitro study.

This study aimed to evaluate the ability of speed of sound (SOS) measured at the phalanges to estimate simulated wrist fracture load and stress. SOS was measured along the proximal phalanges of the second, third and fourth fingers using an ultrasound (US) system operating in axial transmission mode. The bone mineral density (BMD) of the radius and the phalanges was also measured with quantitati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2015