Comparison of two transcutaneous bilirubinometers--Minolta AirShields Jaundice Meter JM103 and Spectrx Bilicheck--in Thai neonates.

نویسندگان

  • Suwimol Sanpavat
  • Issarang Nuchprayoon
چکیده

Transcutaneous bilirubin (TcB) has been reported to have a high correlation with serum bilirubin. The objectives of this study were: (1) to compare the accuracy of two transcutaneous bilirubinometer (Minolto AirShields Jaundice Meter, JM103 (JM) and SpectRx, Bilicheck (BC) in estimating total serum bilirubin (TSB) levels; and (2) to assess the predictive ability of transcutaneous bilirubin in relation to specific selected TSB levels. A total of 154 measurements of TcB, using JM and BC, and TSB were recruited from 134 term and near-term infants. Postnatal ages ranged from 19 to 160 hours (x = 64.7, SD = 25.6). TSB levels ranged from 4.5 to 17.5 mg/dl (x = 10.4, SD = 2.5). The correlation coefficients between TcB (JM and BC) and TSB measurements were significant and similar (r 0.80 and 0.82, respectively). The errors of distribution were, for TSB and TcB-JM, the mean difference of 0.7 mg/dl (SD 1.6 mg/dl and 95% confidence interval of the mean (CI) 0.4 and 1.0]; and, for TSB and TcB-BC, the mean difference of -0.6 mg/dl (SD 1.5 mg/dl and 95% CI -0.4 and -0.8). TcB-JM had a tendency to underestimate TSB levels, and TcB-BC had a tendency to overestimate TSB levels. The sensitivity of BC was higher, but specificity was lower, than JM in corresponding to different TSB levels, except at a TSB level of 15 mg/dl when both instruments yielded 100% sensitivity. The accuracy of JM in predicting TSB was higher than BC at all TSB levels. Operating the JM was simple and uncomplicated. It would be suitable for clinical use when a number of personnel perform the measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of transcutaneous bilirubinometers: SpectRx BiliCheck versus Minolta AirShields.

BACKGROUND Two devices are available for making transcutaneous estimates of serum bilirubin (SBR): the Minolta AirShields JM102 and the new SpectRx BiliCheck. OBJECTIVES (a) To measure how well the readings produced by these devices agree with SBR measured in the laboratory; (b) to estimate for each device, the proportion of infants with clinical jaundice who would require blood sampling if t...

متن کامل

BiliCheck transcutaneous bilirubinometer: a screening tool for neonatal jaundice in the Chinese population.

OBJECTIVE To verify the usefulness of the BiliCheck transcutaneous bilirubin meter as a screening device for neonatal jaundice in a Chinese population compared with the Minolta bilirubin meter. DESIGN A prospective correlation study that compared transcutaneous bilirubin measurements with serum bilirubin levels. SETTING Obstetric ward and a neonatal unit of a regional hospital in Hong Kong....

متن کامل

Archives of Disease in Childhood Fetal and Neonatal Edition 2002;87:F137-F140

TOP ABSTRACT METHODS RESULTS DISCUSSION REFERENCES Background: Two devices are available for making transcutaneous estimates of serum bilirubin (SBR): the Minolta AirShields JM102 and the new SpectRx BiliCheck. Objectives: (a) To measure how well the readings produced by these devices agree with SBR measured in the laboratory; (b) to estimate for each device, the proportion of infants with clin...

متن کامل

The Value of Bilicheck® as a Screening Tool for Neonatal Jaundice in the South of Iran

The gold standard to assess jaundice in neonates is the serum bilirubin measurement. Blood sampling for the determination of total serum bilirubin (TSB) is painful for newborns and stressful for parents. The Bilicheck®, a new transcutaneous bilirubinometer, is considered as a more accurate measurement of bilirubin compared to the previous bilirubinometers courtesy of its advanced technology. Th...

متن کامل

The Value of Bilicheck® as a Screening Tool for Neonatal Jaundice in the South of Iran

The gold standard to assess jaundice in neonates is the serum bilirubin measurement. Blood sampling for the determination of total serum bilirubin (TSB) is painful for newborns and stressful for parents. The Bilicheck®, a new transcutaneous bilirubinometer, is considered as a more accurate measurement of bilirubin compared to the previous bilirubinometers courtesy of its advanced technology. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Southeast Asian journal of tropical medicine and public health

دوره 36 6  شماره 

صفحات  -

تاریخ انتشار 2005