The Importance of Heating System Transient Response in Domestic Energy Labelling
نویسندگان
چکیده
European National Calculation Methods (NCM), such as the UK Standard Assessment Procedure (SAP), are used to make standardised and simplified assessments of building energy performance. These NCMs contain simplifications to aid ease of use and comparability of resulting Energy Performance Certificates (EPC). By comparing SAP with a modern, dynamic modelling system, this study quantifies internal temperatures and thereby heating energy consumption. Results show that for the considered test house SAP results correspond closely to a dynamic model using an idealistic heating system, with perfect control and instant responsiveness. However, the introduction of a dynamic, physically realistic gas fired boiler and water based heating system to the model results in a consistent increase in internal temperature (0.5 ̋C) and energy demand (by ca. 1000 kWh/a). Variation of further parameters within the dynamic model, controls and heat source size, are presented and compared to SAP results and assumptions. The inclusion of more realistic dynamics in building energy modelling for NCMs may provide a better basis for effective decision making with respect to a wide range of heating systems.
منابع مشابه
Comparative performance assessment of flat plate and evacuated tube collectors for domestic water heating systems in Kerman, Iran
This study represents a year-round energy performance of two solar water heating (SWH) systems with a 4m2 flat plate collector (FPC) and an evacuated tube collector (ETC) operating under the same weather conditions. The energy performance of the two considered systems was compared on a monthly and yearly basis. The obtained results showed that for an annual total solar insolation of ...
متن کاملPerformance Study of a Solar Integrated Central Heating System of a Residential Building Using Trnsys- an Hourly Simulation Model (RESEARCH NOTE)
In this investigation, the performance of an existing heating system of a residential building incorporated with an array of solar thermal collectors was studied. For this purpose, transient systems simulation program model was assembled to estimate the hour-by-hour performance of the existing and the system equipped with the solar thermal collectors in terms of the provided space air condition...
متن کاملEconomic optimization and comparative study of solar heat pumps
In this paper, an economic study of solar heat pumps and an investigation of differences between solar heat pumps and conventional heat pumps—based on their performances and energy consumption—are conducted for a residential apartment located in Austin, Texas, USA. Heating in the apartment is provided via a solar heat pump during the cold months of a year. Solar collectors are used to meet the ...
متن کاملComparative study between dynamic transient and degree-hours methods to estimate heating and cooling loads of building’s wall
In this paper, dynamic transient method and conventional degree-hours method (static) have been compared to estimate heating and cooling loads of building’s wall. All main wall surfaces of various orientations, i.e.South, West, East, North, and horizontal are considered in the climate of Tehran, Iran. In this study, a conventional wall structure, which is comprisedconcrete as main wall material...
متن کاملEnergy and Exergy Analysis of a New Power, Heating, Oxygen and Hydrogen Cogeneration Cycle Based on the Sabalan Geothermal Wells
In this paper, a new power, heating and hydrogen cogeneration cycle from Sabalan geothermal two wells is proposed and analyzed. In the proposed system, a new double flash cycle and organic Rankine cycle are used for power production. A proton exchange membrane (PEM) is also used for hydrogen production and the domestic water heater is used for heating. The impacts of some design parameters, suc...
متن کامل