Long-term radiographic assessment of maxillary sinus floor augmentation using beta-tricalcium phosphate: analysis by cone-beam computed tomography

نویسندگان

  • Tsuneji Okada
  • Toru Kanai
  • Noriko Tachikawa
  • Motohiro Munakata
  • Shohei Kasugai
چکیده

BACKGROUND The long-term stability of maxillary sinus floor augmentation with β-TCP remains largely unknown. We report the long-term assessment of volumetric changes in maxillary sinus floor augmentation with β-TCP by cone-beam computed tomography (CBCT). METHODS The subjects included 30 patients who underwent maxillary sinus floor augmentation using β-TCP and 58 implant placement for unilateral maxillary defect, simultaneously. Volumetric changes in β-TCP and the height of peri-implant bone were analyzed by CBCT. RESULTS In all patients, the mean volume of the grafted bone decreased from immediately after implant placement to 6 months after implant placement (75.6 % reduction rate); it decreased further at 2.5 years after implant placement (54.9 % reduction rate). The mean of the height from the implant tip to the maxillary sinus floor was 2.00 ± 1.51 mm, 0.73 ± 1.33 mm, and -0.72 ± 1.11 mm immediately, 6 months, and 2.5 years after implant placement, respectively. The implant tip protruded beyond the maxillary sinus floor in approximately 70 % of the implants (41/58 implants) at 2.5 years after surgery. During the observation period, the implant survival rate was 100 %. CONCLUSIONS The radiographic analysis by CBCT is considerably more advanced than previous radiographic examinations. Although maxillary sinus pneumatization continues to progress ≥1 year after maxillary sinus floor augmentation with β-TCP, it stabilizes 3 years after surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Distance between Posterior Teeth and the Maxillary Sinus Floor Using Cone Beam Computed Tomography

Background and Objectives The topography of the sinus floor and its relationship with maxillary teeth roots varies with age, pneumatization size and grade, positioning of the teeth, and Genetics. This study used cone beam computed tomography (CBCT) to evaluate the distance between posterior teeth and the maxillary sinus floor in patients in Rafsanjan City, Iran. Materials and Methods This de...

متن کامل

The Relation Between Maxillary Sinus Floor and Posterior Maxillary Teeth Roots Using Panoramic and Cone Beam Computed Tomography

Introduction: Understanding the anatomical and pathological relationships between posterior teeth or edentulous area with maxillary sinus is essential for diagnosis and treatment management.The present study aimed to assess the relationship between maxillary sinus floor and posterior teeth roots using panoramic radiography and Cone Beam Computed Tomography (CBCT). Materials and Methods: In thi...

متن کامل

Remodeling of Autogenous Bone Grafts after Osteotome Sinus Floor Elevation Assessed by Limited Cone Beam Computed Tomography

This study assessed the radiographic appearance of bone graft domes longitudinally after osteotome sinus floor elevation using cone beam computed tomography (CBCT). This study presents the radiological findings of a 6-month follow-up CBCT study in maxillary osteotome sinus floor elevation. We examined 52 patients with a crestal bone height of less than 8 mm in the posterior maxilla who required...

متن کامل

Complications of postoperative swelling of the maxillary sinus membrane after sinus floor augmentation

Maxillary sinus floor augmentations were performed by the lateral window technique in 132 sites using betatricalcium phosphate (β-TCP) granules. Cone beam computed tomography (CBCT) scans were taken before surgery, the day of surgery, and one week, three months and one year after surgery. The proportion of the area of the postoperative swelling of the sinus membrane in relation to the remaining...

متن کامل

Evaluation of prevalence and pattern of maxillary sinus mucosal thickening in cone beam computed tomography of dental implant candidates in Shiraz, Iran

BACKGROUND AND AIM: This study aimed to assess maxillary sinus floor membrane thickness and ostium patency (OP) in patients undergoing cone beam computed tomography (CBCT) evaluation for implant placement in the posterior maxilla. Mucosal thickening (MT) could be cause of post-operative complications in implant procedures; awareness of this incidence could help proper detection and further succ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2016