A dual propagation contours technique for semi-automated assessment of systolic and diastolic cardiac function by CMR

نویسندگان

  • Wei Feng
  • Hosakote Nagaraj
  • Himanshu Gupta
  • Steven G Lloyd
  • Inmaculada Aban
  • Gilbert J Perry
  • David A Calhoun
  • Louis J Dell'Italia
  • Thomas S Denney
چکیده

BACKGROUND Although cardiovascular magnetic resonance (CMR) is frequently performed to measure accurate LV volumes and ejection fractions, LV volume-time curves (VTC) derived ejection and filling rates are not routinely calculated due to lack of robust LV segmentation techniques. VTC derived peak filling rates can be used to accurately assess LV diastolic function, an important clinical parameter. We developed a novel geometry-independent dual-contour propagation technique, making use of LV endocardial contours manually drawn at end systole and end diastole, to compute VTC and measured LV ejection and filling rates in hypertensive patients and normal volunteers. METHODS 39 normal volunteers and 49 hypertensive patients underwent CMR. LV contours were manually drawn on all time frames in 18 normal volunteers. The dual-contour propagation algorithm was used to propagate contours throughout the cardiac cycle. The results were compared to those obtained with single-contour propagation (using either end-diastolic or end-systolic contours) and commercially available software. We then used the dual-contour propagation technique to measure peak ejection rate (PER) and peak early diastolic and late diastolic filling rates (ePFR and aPFR) in all normal volunteers and hypertensive patients. RESULTS Compared to single-contour propagation methods and the commercial method, VTC by dual-contour propagation showed significantly better agreement with manually-derived VTC. Ejection and filling rates by dual-contour propagation agreed with manual (dual-contour - manual PER: -0.12 +/- 0.08; ePFR: -0.07 +/- 0.07; aPFR: 0.06 +/- 0.03 EDV/s, all P = NS). However, the time for the manual method was approximately 4 hours per study versus approximately 7 minutes for dual-contour propagation. LV systolic function measured by LVEF and PER did not differ between normal volunteers and hypertensive patients. However, ePFR was lower in hypertensive patients vs. normal volunteers, while aPFR was higher, indicative of altered diastolic filling rates in hypertensive patients. CONCLUSION Dual-propagated contours can accurately measure both systolic and diastolic volumetric indices that can be applied in a routine clinical CMR environment. With dual-contour propagation, the user interaction that is routinely performed to measure LVEF is leveraged to obtain additional clinically relevant parameters.

منابع مشابه

Detecting left ventricular impaired relaxation in cardiac MRI using moving mesh correspondences

UNLABELLED Anatomical cine cardiovascular magnetic resonance (CMR) imaging is widely used to assess the systolic cardiac function because of its high soft tissue contrast. Assessment of diastolic LV function has not regularly been performed due the complex and time consuming procedures. This study presents a semi-automated assessment of the left ventricular (LV) diastolic function using anatomi...

متن کامل

Automated frame-by-frame endocardial border detection from cardiac magnetic resonance images for quantitative assessment of left ventricular function: validation and clinical feasibility.

PURPOSE To develop a technique based on image noise distribution for automated endocardial border detection from cardiac magnetic resonance (CMR) images throughout the cardiac cycle, validate it, and test its clinical utility. MATERIALS AND METHODS Images obtained in 36 patients were analyzed using custom software to obtain left ventricular (LV) volume throughout the cardiac cycle, end-systol...

متن کامل

Automated segmentation of routine clinical cardiac magnetic resonance imaging for assessment of left ventricular diastolic dysfunction.

BACKGROUND Cardiac magnetic resonance (CMR) is established for assessment of left ventricular (LV) systolic function but has not been widely used to assess diastolic function. This study tested performance of a novel CMR segmentation algorithm (LV-METRIC) for automated assessment of diastolic function. METHODS AND RESULTS A total of 101 patients with normal LV systolic function underwent CMR ...

متن کامل

Manual correction of semi-automatic three-dimensional echocardiography is needed for right ventricular assessment in adults; validation with cardiac magnetic resonance

BACKGROUND Three-dimensional echocardiography (3DE) and semi-automatic right ventricular delineation has been proposed as an appropriate method for right ventricle (RV) evaluation. We aimed to examine how manual correction of semi-automatic delineation influences the accuracy of 3DE for RV volumes and function in a clinical adult setting using cardiac magnetic resonance (CMR) as the reference m...

متن کامل

Evaluation of diastolic function by three-dimensional volume tracking of the mitral annulus with cardiovascular magnetic resonance: comparison with tissue Doppler imaging

BACKGROUND Measurement of mitral annulus (MA) dynamics is an important component of the evaluation of left ventricular (LV) diastolic function; MA velocities are commonly measured using tissue Doppler imaging (TDI). This study aimed to examine the clinical potential of a semi-automated cardiovascular magnetic resonance (CMR) technique for quantifying global LV diastolic function, using 3D volum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • Journal of Cardiovascular Magnetic Resonance

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2009