Real-time detection of Escherichia coli O157:H7 sequences using a circulating-flow system of quartz crystal microbalance.

نویسندگان

  • Vivian C H Wu
  • Sz-Hau Chen
  • Chih-Sheng Lin
چکیده

A DNA piezoelectric biosensing method for real-time detection of Escherichia coli O157:H7 in a circulating-flow system was developed in this study. Specific probes [a 30-mer oligonucleotide with or without additional 12 deoxythymidine 5'-monophosphate (12-dT)] for the detection of E. coli O157:H7 gene eaeA, synthetic oligonucleotide targets (30 and 104 mer) and PCR-amplified DNA fragments from the E. coli O157:H7 eaeA gene (104 bp), were used to evaluate the efficiency of the probe immobilization and hybridization with target DNA in the circulating-flow quartz crystal microbalance (QCM) device. It was found that thiol modification on the 5'-end of the probes was essential for probe immobilization on the gold surface of the QCM device. The addition of 12-dT to the probes as a spacer, significantly enhanced (P<0.05) the hybridization efficiency (H%). The results indicate that the spacer enhanced the H% by 1.4- and 2-fold when the probes were hybridized with 30- and 104-mer targets, respectively. The spacer reduced steric interference of the support on the hybridization behavior of immobilized oligonucleotides, especially when the probes hybridized with relatively long oligonucleotide targets. The QCM system was also applied in the detection of PCR-amplified DNA from real samples of E. coli O157:H7. The resultant H% of the PCR-amplified double-strand DNA was comparable to that of the synthetic target T-104AS, a single-strand DNA. The piezoelectric biosensing system has potential for further applications. This approach lays the groundwork for incorporating the method into an integrated system for rapid PCR-based DNA analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PCR detection of Escherichia coli O157:H7 directed from slaughtered cattle in Shiraz, Iran

  Escheric hia coli O157:H7 lives in the intestines of healthy cattle, and can contaminate meat during slaughtering pr actices . Detection of the low infectious dosage of bacterium requires a sensitive method. We developed polymerase chain reaction (PCR) assays to detect the gene Stx2 irrespective of the bacterial serotype. In this study, the detection limit of the PCR protocol in detecting Stx...

متن کامل

Real-time reverse transcription-multiplex PCR for simultaneous and specific detection of rfbE and eae genes of Escherichia coli O157:H7.

A real-time reverse transcription multiplex polymerase chain reaction (rRT-MPCR) was developed for detection of mRNA encoded by rfbE and eae genes of enterohemorrhagic Escherichia coli (EHEC) O157:H7. A 129-bp and a 106-bp sequence specific to rfbE and eae, respectively, were targeted for reverse transcription, amplification, and real-time detection. A single-step RT-PCR kit containing a mixtur...

متن کامل

Identification of Escherichia coli O157: H7 from Slaughtered Beef in Mashhad Using Biochemical and Molecular Methods

Background and Aims: Escherichia coli O157:H7 is one of the main causes of transmitted diseases by food, including meat and meat products. The purpose of this study was to investigate the prevalence of E. coli O157:H7 contamination in Mashhad with the detection of rfbE gene. Materials and Methods: For this study, 148 slaughtered beef samples from Mashhad (spring to winter, 2018) were randomly ...

متن کامل

Detection of Viable But Non-Culturable State of Escherichia coli O157:H7 Using Reverse Transcription PCR

Background and Aims: Many bacteria including Escherichia coli may enter into a viable but non-culturable (VBNC) state under unfavorable stresses, which are unable to be detected by culture-based methods. In this study, the use of Reverse Transcription PCR (RT-PCR) for detection of VBNC state of E. coli O157:H7 was investigated. Materials and Methods:  Escherichia. coli O157:H7 was inoculated i...

متن کامل

Use of the duplex TaqMan PCR system for detection of Shiga-like toxin-producing Escherichia coli O157.

Real-time PCR assays have been applied for the detection and quantification of pathogens in recent years. In this study two combinations of primers and fluorescent probes were designed according to the sequences of the rfb(Escherichia coli O157) and stx2 genes. Analysis of 217 bacterial strains demonstrated that the duplex real-time PCR assay successfully distinguished the Escherichia coli O157...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 22 12  شماره 

صفحات  -

تاریخ انتشار 2007