Safety and Functionality of a Guidewire Fixator
نویسندگان
چکیده
OBJECTIVE A new endovascular tool, the Liungman Guidewire Fixator, has been developed to simplify endovascular treatment in complex aortic aneurysms. The device has been extensively tested in bench models and animal trials. To verify the safety and functionality demonstrated in the porcine model, the device was tested in ten patients undergoing endovascular aortic repair (EVAR) or fenestrated endovascular aortic repair (f-EVAR) treatment for abdominal aortic aneurysm. METHODS The Liungman Guidewire Fixator consists of a braided stent-like, cylindrical structure with conical ends and a central channel for a 0.035″ guidewire. When in use, it is slid along the guidewire and positioned in the target artery, where the Liungman Guidewire Fixator interacts with the arterial wall by anchoring the guidewire to the wall through a radial force. The Liungman Guidewire Fixator allows for uninterrupted blood flow passed the point of fixation. In this study, the Liungman Guidewire Fixator was tested in ten patients undergoing EVAR or f-EVAR treatment for abdominal aortic aneurysm. The device was deployed and retrieved crossover into the hypogastric artery, and the occurrence of thrombotic occlusion, arterial dissection, and vascular rupture or trauma was studied using angiography, as well as device ability to withstand guidewire tension. RESULTS There were no instances of occlusion, dissection, or vascular trauma detected using angiography. In all cases, deployment and retrieval were successful, and the devices could withstand an applied tension of 3 N. In one instance, retrieval was challenging because of significant tortuosity, which was resolved by a coaxial catheterization. CONCLUSIONS Deployment was uneventful in all ten patients. Retrieval according to the intended instruction for use was performed in nine of the patients. In one patient, a coaxial catheterization was necessary. All devices withstood a retention force of 3 N.
منابع مشابه
Precannulated Fenestrated Endovascular Aneurysm Repair Using Guidewire Fixator
OBJECTIVE By using a guidewire fixator, the distal guidewire position can be secured in an artery. This new principle enables a method for fenestrated endovascular aortic repair where the connection between the aortic branches and the stent graft fenestrations is made before inserting and deploying the stent graft. METHODS This is conducted using a fenestrated stent graft with preloaded cathe...
متن کاملNasopharyngeal tube placement in emergency intubated patients with decreased consciousness with a new guidewire: a prospective randomized controlled trial
Background: There is some demand for nasogastric tube insertion in unconscious or ICU patients. Nasogastric tubes are generally made of flexible plastic materials, prone to twisting and deviation by the tracheal tube, when passing through the pharynx and esophageal opening, making it difficult to insert the NG-tube properly. We hypothesized that NG-tube insertion with help of guidewire can sign...
متن کاملTreatment of Pediatric Open Femoral Fractures with External Fixator Versus Flexible Intramedullary Nails
Background: In children, inappropriate treatment of open femoral fractures may induce several complications. A few studies have compared the external fixator with flexible intramedullary nails in high-grade open femoral fractures of children. The present study aims at comparing results of these two treatment methods in open femoral fractures. Methods: In this descriptive analytical study, 27 ...
متن کاملNovel device, a temporary guidewire fixator
A novel device for distal fixation of a guidewire was tested in regards to deployment and retrieval, deposition in the blood stream and force of fixation in a pig model. Eleven pigs were subjected to full anaesthesia and heparinized to active clotting time 250-350 s. Uninterrupted blood flow during 4 h deposition was assessed by angiography and inspected for thrombus deposition upon retrieval. ...
متن کاملImpact of guidewire selection and operator expertise on radiation exposure in transradial angiography
BACKGROUND Several studies have implied that the time of radiation exposure for patients and operators during the transradial approach for coronary angiography (TRA) is associated with the use of different guidewire or catheter and operator's finesse. This study aimed to assess the effects of non-hydrophilic or hydrophilic guidewire and operator expertise on fluoroscopy time and procedure time ...
متن کامل