Development and comparison of automated classifiers for glaucoma diagnosis using Stratus optical coherence tomography.
نویسندگان
چکیده
PURPOSE To develop and compare the ability of several automated classifiers to differentiate between normal and glaucomatous eyes based on the quantitative assessment of summary data reports from Stratus optical coherence tomography (OCT; Carl Zeiss Meditec Inc., Dublin, CA) in a Chinese population in Taiwan. METHODS One randomly selected eye from each of 89 patients with glaucoma and each of 100 age- and sex-matched normal individuals were included in the study. Measurements of glaucoma variables (retinal nerve fiber layer thickness and optic nerve head analysis results) were obtained by Stratus OCT. With the Stratus OCT parameters used as input, receiver operative characteristic (ROC) curves were generated by three methods, to classify eyes as either glaucomatous or normal: linear discriminant analysis (LDA), Mahalanobis distance (MD), and artificial neural network (ANN). The area under the ROC curve was optimized by principal component analysis (PCA). Classification accuracy was determined by cross validation. RESULTS The average visual field mean deviation was -0.7 +/- 0.6 dB in the normal group and -2.7 +/- 1.9 dB in the glaucoma group. The areas under the ROC curves were 0.824 (LDA), 0.849 (MD), 0.821 (ANN), 0.915 (LDA with PCA), 0.991 (MD with PCA), and 0.874 (ANN with PCA). CONCLUSIONS With Stratus OCT parameters used as input, automated classifiers show promise for discriminating between glaucomatous and normal eyes. MD measured from multivariate data can predict the severity of glaucoma through the construction of a measurement space. After PCA, implementation results show that the Mahalanobis space created by MD surpasses LDA and ANN in diagnosing glaucoma.
منابع مشابه
The Relationship between Optical Coherence Tomography and Scanning Laser Polarimetry Measurements in Glaucoma
PURPOSE To investigate the relationship between optical coherence tomography (OCT) and scanning laser polarimetry (SLP) in measuring peripapillary retinal nerve fiber layer (RNFL) thickness in glaucomatous eyes. METHODS Fifty glaucomatous eyes were evaluated in this study. Evaluations were analyzed two ways. First, parameters of the Stratus OCT (average thickness, superior/inferior average) a...
متن کاملComparison of glaucoma diagnostic Capabilities of Cirrus HD and Stratus optical coherence tomography.
OBJECTIVE To compare the glaucoma diagnostic capabilities offered by Stratus and Cirrus spectral-domain optical coherence tomography (OCT). METHODS One hundred subjects with glaucoma and 74 healthy subjects were tested by Stratus and Cirrus OCT. Areas under the receiver operating characteristic curves (AUCs) of average, 4-quadrant, and 12-sector retinal nerve fiber layer thicknesses and sensi...
متن کاملAccuracy of the retinal nerve fiber layer measurements by Stratus optical coherence tomography for perimetric glaucoma.
OBJECTIVE To calculate the sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of measurements of the retinal nerve fiber layer using the Stratus optical coherence tomography in glaucoma subjects with visual field defects on achromatic perimetry as the gold standard. STUDY DESIGN Comparative cross-sectional. PLACE AND DURATION OF STUDY Outd...
متن کامل[Diagnostic ability of stratus optical coherence tomography (OCT) in pre-perimetric glaucoma diagnosis].
OBJECTIVE To compare retinal nerve fiber layer (RNFL) measurements performed with Stratus OCT 3000 in normal, ocular hypertensive, pre-perimetric and glaucomatous eyes. METHODS 98 normal subjects, 156 ocular hypertensives with short-wavelength automated perimetry (SWAP), 21 ocular hypertensives with altered SWAP (pre-perimetric glaucoma) and 66 glaucomatous eyes were included in the study. Di...
متن کاملCirrus high-definition optical coherence tomography compared with Stratus optical coherence tomography in glaucoma diagnosis.
PURPOSE To compare the retinal nerve fiber layer (RNFL) evaluation using Cirrus optical coherence tomography (OCT) and Stratus OCT in glaucoma diagnosis. METHODS One hundred thirty normal and 86 patients with glaucoma were included in this prospective study. The signal strengths of the OCTs were evaluated. The sensitivities and specificities of global RNFL average thickness were compared in t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 46 11 شماره
صفحات -
تاریخ انتشار 2005