Where is the human waist? Definitions, manual compared toscanner measurements.

نویسنده

  • Daisy Veitch
چکیده

Where exactly is the human waist? How do definitions work for women who deviate from the conventional body shape? Does the measuring instrument matter? Waist is conventionally understood to be a measurable zone within the abdominal region of the torso, a zone of considerable importance. There needs to be a good consistent waist definition, one accurate and valid for everyone. Incorrect definition and measurement will result in technical errors, commercial wastage and customer dissatisfaction. This paper investigates the waist's location and size from the point of view of garment construction for 90 adult women scanned and manually measured in a breast reduction study at Flinders Medical Center, South Australia. There are differing definitions of the location of the human waist as well as different measuring instruments. This study compares:• Two definitions:• ISO 8559, 2.1.11 and • CAESAR, Waist Circumference Preferred.• Two different instruments:• the traditional tape measure, and • software-extracted computer-aided anthropometry (CAA). Substantial discrepancies between the results from these two locations-definitions were found. The choice of instrument used seriously affects the measurement obtained. This study demonstrates three things:• waist is not horizontal for a significant sub group of the population,• CAA extracted waist measurements are not accurate (same as real values) or valid (measures the characteristic) for a sub group, and • manually measured CAESAR Preferred Waist accurately and validly measured all individuals studied. There is a clear need to modify ISO waist definition for garment construction to include the full range of anatomical variation encountered amongst women.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Accuracy of Waist-Hip Ratio Calculation by the BIA device versus the Manual Method

Nowadays, the Waist-Hip Ratio is considered one of the most important indices in predicting the risk of cardiovascular diseases. The usual method for calculating this index is by measuring the waist and hip circumferences with a measuring tape. However, bioelectrical impedance analysis (BIA) devices are also capable of calculating this ratio. Hence, the goal of this study was to calculate this ...

متن کامل

Automatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images

Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...

متن کامل

Development of Three Dimensional Automatic Body Fat Measurement Software from CT, and Its Validation and Evaluation

Abdominal obesity describes the accumulation of excessive fat in the abdomen. It is known that depending on its distribution, visceral obesity presents a greater danger to health than subcutaneous obesity. To properly prevent and treat visceral obesity, accurate evaluation methods are necessary, and hence quantitative VAT estimation is extremely important. CT scans are the most accurate method ...

متن کامل

Measurement of Waist and Hip Circumference with a Body Surface Scanner: Feasibility, Validity, Reliability, and Correlations with Markers of the Metabolic Syndrome

OBJECTIVE Body surface scanners (BS), which visualize a 3D image of the human body, facilitate the computation of numerous body measures, including height, waist circumference (WC) and hip circumference (HC). However, limited information is available regarding validity and reliability of these automated measurements (AM) and their correlation with parameters of the Metabolic Syndrome (MetS) com...

متن کامل

Extraction of the Longitudinal Movement of the Carotid Artery Wall using Consecutive Ultrasonic Images: a Block Matching Algorithm

Introduction: In this study, a computer analysis method based on a block matching algorithm is presented to extract the longitudinal movement of the carotid artery wall using consecutive ultrasonic images. A window (block) is selected as the reference block in the first frame and the most similar block to the reference one is found in the subsequent frames. Material and Methods: The program was...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Work

دوره 41 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2012