Investigation of the effect of subcutaneous fat on image quality performance of 2D conventional imaging and tissue harmonic imaging.

نویسندگان

  • Jacinta E Browne
  • Amanda J Watson
  • Peter R Hoskins
  • Alex T Elliott
چکیده

Tissue harmonic imaging (THI) has been reported to improve contrast resolution, tissue differentiation and overall image quality in clinical examinations. However, a study carried out previously by the authors (Brown et al. 2004) found improvements only in spatial resolution and not in contrast resolution or anechoic target detection. This result may have been due to the homogeneity of the phantom. Biologic tissues are generally inhomogeneous and THI has been reported to improve image quality in the presence of large amounts of subcutaneous fat. The aims of the study were to simulate the distortion caused by subcutaneous fat to image quality and thus investigate further the improvements reported in anechoic target detection and contrast resolution performance with THI compared with 2D conventional imaging. In addition, the effect of three different types of fat-mimicking layer on image quality was examined. The abdominal transducer of two ultrasound scanners with 2D conventional imaging and THI were tested, the 4C1 (Aspen-Acuson, Siemens Co., CA, USA) and the C5-2 (ATL HDI 5000, ATL/Philips, Amsterdam, The Netherlands). An ex vivo subcutaneous pig fat layer was used to replicate beam distortion and phase aberration seen clinically in the presence of subcutaneous fat. Three different types of fat-mimicking layers (olive oil, lard and lard with fish oil capsules) were evaluated. The subcutaneous pig fat layer demonstrated an improvement in anechoic target detection with THI compared with 2D conventional imaging, but no improvement was demonstrated in contrast resolution performance; a similar result was found in a previous study conducted by this research group (Brown et al. 2004) while using this tissue-mimicking phantom without a fat layer. Similarly, while using the layers of olive oil, lard and lard with fish oil capsules, improvements due to THI were found in anechoic target detection but, again, no improvements were found for contrast resolution for any of the layer combinations. Therefore, it was felt that the lack of improvement in contrast resolution performance may be due to the test phantom design and not to whether a layer was present that caused beam distortion and phase aberrations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An improvement in RTM method to image steep dip petroleum bearing structures and its superiority to other methods

In this paper, first the limitations of the ray-based method and the one-way wave-field extrapolation migration (WEM) in imaging steeply dipping structures are discussed by some examples. Then a new method of the reverse time migration (RTM), used in imaging such complex structures is presented. The proposed method uses a new wave-field extrapolator called the Leapfrog-Rapid Expansion Method (L...

متن کامل

اندازه‌گیری ضخامت چربی زیرپوستی در تصاویر مادون قرمز در لیپوساکشن: گزارش کوتاه

Background: Currently, there are many techniques to measure subcutaneous body fat but these methods have many limitations. In this study, we tried to provide a clustering algorithm to measure the thickness of subcutaneous fat in thermography images. Methods: For the detection of subcutaneous adipose tissue in the midline area (from pubis to the xiphoid process), imaging takes place in the righ...

متن کامل

Tissue Doppler Imaging versus Conventional Echocardiography in Evaluation of Cardiac Functions in Diabetes Mellitus

Background: Conventional echocardiography and tissue Doppler imaging have been highlighted to diagnose diastolic and systolic heart dysfunction. We aimed to compare tissue Doppler imaging with conventional echocardiography to diagnose heart dysfunctions in diabetes mellitus type 1 (DMT1) patients. <s...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Performance Evaluation of FBP Reconstruction in SPECT Imaging

Introduction:  The  purpose  of  this  study  is  to  define  the  optimal  parameters  for  the  tomographic  reconstruction procedure in a routine single photon emission tomography. The Hoffman brain phantom  is modified to evaluate the reconstruction method. The phantom was imaged in a 3 and 2-dimensional  conformation and the results were compared.   Materials  and  Methods:  The  2D  phant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 31 7  شماره 

صفحات  -

تاریخ انتشار 2005