Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency.

نویسندگان

  • Vibhas S Deshpande
  • Steven M Shea
  • Debiao Li
چکیده

The presence of resonance frequency offsets often causes artifacts in images acquired with true fast imaging with steady-state precession (true-FISP). One source of resonance offsets is a suboptimal setting of the synthesizer frequency. The goal of this work was to demonstrate that shifting the synthesizer frequency could minimize the off-resonance related image artifacts in true-FISP. A simple scouting method was developed to estimate the optimal synthesizer frequency for the volume of interest (VOI). To improve fat suppression, a similar scouting method was also developed to determine the optimal frequency offset for the fat saturation pulse. Coronary artery imaging was performed in healthy subjects using a 3D true-FISP sequence to validate the effectiveness of the frequency corrections. Substantial reduction in image artifacts and improvement in fat suppression were observed by using the water and fat frequencies estimated by the scouting scans. Frequency shifting is a useful and practical method for improving coronary artery imaging using true-FISP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Systemic atherosclerotic plaque vulnerability in patients with Coronary Artery Disease with a single Whole Body [FDG]PET-CT scan

Objective(s): Cardiovascular disease is a leading cause of morbimortality with over half cardiovascular events occurring in the asymptomatic population by traditional risk stratification. This preliminary study aimed to evaluate systemic plaque vulnerability in patients with prior Coronary Artery Disease (CAD) with a single Whole Body [FDG] PET-CT scan in terms of plaq...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

STRUCTURE AND FUNCTION Rapid Evaluation of Right and Left Ventricular Function and Mass Using Real-Time True-FISP Cine MR Imaging Without Breath-Hold: Comparison with Segmented True-FISP Cine MR Imaging with Breath-Hold

Purpose. To evaluate the accuracy of cardiac function measured with real-time true fast imaging with steady-state precession (True-FISP) cine without breath-hold compared with those measured from segmented True-FISP cine with breath-hold. Methods. Eighteen consecutive patients and six healthy volunteers were enrolled in the study group. Both realtime multislice True-FISP cine imaging without br...

متن کامل

Evaluation of Metal Artifact Reduction software in Computed Tomography

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 49 5  شماره 

صفحات  -

تاریخ انتشار 2003