Finite element analysis of the equivalent stress distribution in Schanz screws during the use of a femoral fracture distractor☆

نویسندگان

  • Vincenzo Giordano
  • Alexandre Leme Godoy-Santos
  • William Dias Belangero
  • Robinson Esteves Santos Pires
  • Pedro José Labronici
  • Hilton Augusto Koch
چکیده

To evaluate the mechanical stress and elastic deformation exercised in the thread/shaft transition of Schanz screws in assemblies with different screw anchorage distances in the entrance to the bone cortex, through the distribution and location of tension in the samples. An analysis of 3D finite elements was performed to evaluate the distribution of the equivalent stress (triple stress state) in a Schanz screw fixed bicortically and orthogonally to a tubular bone, using two mounting patterns: (1) thread/shaft transition located 20 mm from the anchorage of the Schanz screws in the entrance to the bone cortex and (2) thread/shaft transition located 3 mm from the anchorage of the Schanz screws in entrance to the bone cortex. The simulations were performed maintaining the same direction of loading and the same distance from the force vector in relation to the center of the hypothetical bone. The load applied, its direction, and the distance to the center of the bone were constant during the simulations in order to maintain the moment of flexion equally constant. The present calculations demonstrated linear behavior during the experiment. It was found that the model with a distance of 20 mm between the Schanz screws anchorage in the entrance to the bone cortex and the thread/shaft transition reduces the risk of breakage or fatigue of the material during the application of constant static loads; in this model, the maximum forces observed were higher (350 MPa). The distance between the Schanz screws anchorage at the entrance to the bone cortex and the smooth thread/shaft transition of the screws used in a femoral distractor during acute distraction of a fracture must be farther from the entrance to the bone cortex, allowing greater degree of elastic deformation of the material, lower mechanical stress in the thread/shaft transition, and minimized breakage or fatigue. The suggested distance is 20 mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis

Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...

متن کامل

Evaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method

 longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...

متن کامل

Stress Distribution in Four Restorative Methods in Endodontically Treated Maxillary Premolar: A 3D Finite Element Analysis

Introduction: the Restoration of endodontically treated teeth is critical, and the Awareness of stresses developed by oblique and vertical forces in restorative methods take a great role in treatment plans. Due to the anatomical shape and inherent form of the stress distribution premolars, could be lost by fractures. Some fractures such as vertical fracture which is probable in...

متن کامل

Using the Finite Element Analysis Method to Study the 3-point Bending Test for the Characterization of the Adherence

An elastic finite element analysis was conducted to evaluate the stress distribution in the initiation zone of the adhesive rupture during the 3-point bending test. This test is used to measure the adherence between a polyepoxy adhesive and aluminum alloy with different surface treatments. The purpose is to compare, in the high stress concentration areas, the stress fields calculated using fini...

متن کامل

The Effect of Post Material on Stress Distribution in Mandibular Second Premolar Tooth by Finite Element Analysis

Introduction: The restoration material commonly used as core material for pulpless posterior teeth is mostly amalgam due to its high strength and low cost and it can be used with or without pin. The aim of this study was to evaluate the influence of post material on stress distribution in mandibular second premolar tooth by finite element analysis. Method: The stress distribution was analyzed i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 52  شماره 

صفحات  -

تاریخ انتشار 2017