Pulmonary injury associated with spray of a water-based nano-sized waterproofing product: a case study
نویسندگان
چکیده
Background In most reported cases of lung trauma with water proofing products, volatile organic compounds (VOC) have a prominent role. Here we report on a case involving ten workers exposed to a sprayed product containing nanoparticles in a water solution with only a few percent VOC. Case presentation Ten workers suffered from respiratory symptoms following spray impregnation of hardwood furniture using a waterproofing product that contained positively charged fluorinated acrylate copolymer solid cores with a median diameter of 70 nm (1.3 w%) in aqueous suspension with 3.3 w% VOC and 0.3 w% quaternary ammonium. The worker who applied one liter of the product in a wood workshop, using an air mix spray gun, did not report any health complaints. Another worker, who entered the workshop 3 h later and had rolled and smoked two cigarettes, was hospitalized with severe chemical pneumonitis. A chest X-ray (CXR) showed bilateral infiltrative impairment in the lower lobe regions. On the next day a second CXR showed increased patchiness marking in all fields. A high-resolution Computer Tomography (CT)-scan demonstrated extensive bilateral areas of ground-glass opacities predominantly in the lower regions of the upper lobes, the right middle lobe and the apical regions of the lower lobes, compatible with severe chemical pneumonitis. On the following morning, nine workers in an adjacent workplace in the same building, experienced dry cough, chest tightness and substernal pain upon physical exercise. Reconstruction of the spray application in a climate chamber confirmed trimethyl silanol, glycol ethers and fluoroalkenes in the gas phase. Immediately after the spray application, aerosols were observed at a maximum concentration of 6.3 × 104 cm-3. Mass concentrations were 0.095 and 10 mg/m3 in the size ranges 5.6-560 nm and 0.22-30 μm, respectively, decreasing to less than 10 μg/m3 in both size ranges after 15 h. Conclusion The hospitalized worker had smoked cigarettes contaminated with fluoropolymers which is a plausible explanation for the lung trauma. Respiratory symptoms in the nine workers may be caused by inhalation of particles that became airborne by resuspension from surfaces when workers entered the adjacent workplace the next day. A contribution from VOC appears less likely because measurements and modelling showed that concentrations in the mg/m3 range could have occurred only if the building was assumed to be completely airtight.
منابع مشابه
Mechanism of Action of Lung Damage Caused by a Nanofilm Spray Product
Inhalation of waterproofing spray products has on several occasions caused lung damage, which in some cases was fatal. The present study aims to elucidate the mechanism of action of a nanofilm spray product, which has been shown to possess unusual toxic effects, including an extremely steep concentration-effect curve. The nanofilm product is intended for application on non-absorbing flooring ma...
متن کاملDiffuse alveolar hemorrhage after use of a fluoropolymer-based waterproofing spray
A 30-year-old man developed chills, cough and dyspnea a few minutes after using a fluoropolymer-based waterproofing spray in a small closed room. He visited our hospital 1 h later. Examination revealed that the patient had incessant cough, tachypnea, fever and decreased peripheral arterial oxygen saturation. Blood tests revealed leukocytosis with elevated serum C-reactive protein levels. Chest ...
متن کاملOzone Resistance, Water Permeability, and Concrete Adhesion of Metallic Films Sprayed on a Concrete Structure for Advanced Water Purification
We evaluated the applicability of metal spray coating as a waterproofing/corrosion protection method for a concrete structure used for water purification. We carried out an ozone resistance test on four metal sprays and evaluated the water permeability and bond strength of the metals with superior ozone resistance, depending on the surface treatment method. In the ozone resistance test, four me...
متن کاملProperties of Nanostructured Hydroxyapatite Prepared by a Spray Drying Technique
In previous studies nano sized hydroxyapatite (HA) particles were prepared by solgel or precipitation methods, in which the products were washed by aqueous or non-aqueous liquids to remove impurities or undesired components. The washing is know to modify the surfaces of the cystalline particles. This study evaluated properties of nano HA materials prepared by a spray drying method in which the ...
متن کاملInvestigation of Products Distribution In Fischer-Tropsch Synthesis By Nano-sized Iron-based Catalyst
Nano-sized iron-based catalyst was prepared by the micro-emulsion method. The composition of the final nano-sized iron catalyst, in term of the atomic ratio contains: 100Fe/4Cu/2Ce. Experimental techniques of XRD, BET, TEM and TPR were used to study the phase, structure and morphology of the catalyst. Fischer-Tropsch Synthesis (FTS) reaction test was performed in a fixed bed reactor at pressure...
متن کامل