Short Communication Dependence of Blood Viscosity on Haematocrtt and Shear Rate in a Primitive Vertebrate

نویسندگان

  • R. M. G. WELLS
  • M. E. FORSTER
چکیده

Hagfish have an unusual circulation with intravascular pressures that are lower than those in other vertebrates (Davie et al. 1987; Forster, 1989) and since peripheral resistances appear similar to those of teleost fishes (Rood, 1979; Elger, 1987), it follows that blood flow rates will also be lower. One might therefore predict that the relatively low haematocrits in hagfish (Johansen et al. 1962; Forster et al. 1989) and lack of plasma albumins (Manwell, 1963) would maintain a relatively low blood viscosity at low flow rates when blood tends to become more viscous by virtue of its non-Newtonian behaviour (McDonald, 1974; Fletcher & Haedrich, 1987). Viscosity measurements were made on the blood and plasma of the hagfish, Eptatretus cirrhatus (Forster), to determine whether blood viscosity was unusually low in a vertebrate with a circulation operating at low shear rates, and to see whether this primitive vertebrate conformed to optimal haematocrit theory (cf. Crowell & Smith, 1967). Hagfish were cannulated via the ventral aorta, and maintained in running sea water. Heparinized whole blood was drawn for measurements of viscosity, haematological parameters and total plasma protein (Biuret reaction). Packed erythrocytes were resuspended in autologous plasma to provide a series of haematocrits (Hct) from 0 to 40 %. The viscosity of 0-5 ml samples was measured at 20°C in a rotating cone-plate viscometer (model LVTD, Brookfield Engineering, Stoughton, MA) equipped with cone angle of 0-8° (Fig. 1). Haematological data are summarized in Table 1. The linear dimensions for hagfish erythrocytes were about twice those reported for teleost fishes (e.g. Hughes et al. 1982; Hughes & Kikuchi, 1984). A comparison of vertebrate erythrocytes with widely differing sizes led Chien et al. (1971) to the conclusion that erythrocyte volume was not an important determinant of blood viscosity. The mean ventral aortic Hct value reported here of 12-6% is low among vertebrates. Total plasma protein in the hagfish was about half that recorded for teleosts (Graham & Fletcher, 1985), no doubt because of the absence of albumin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AXIAL FLOW IN A ROTATIONAL COAXIAL RHEOMETER SYSTEM 1. BINGHAM PLASTIC

A mathematical analysis has been carried out for the axial flow of a Bingham plastic fluid, in the Concentric Cylinder Viscometer which consists of a cylindrical sample holder (the cup) and a cylindrical spindle (the bob) coaxial with the cup. The fluid to be tested flows through the annular gap of the cup and the bob system, sheared by the rotation of the inner cylinder, while the outer cy...

متن کامل

AXIAL FLOW IN A ROTATIONAL COAXIAL RHEOMETER SYSTEM 11: HERSCHEL BULKLEY MODEL

Following recent works of several authors like Huilgol, Bhattacharya etd. and Javadpour et al., this paper is to contribute further to the literature of axial flow in a rotational coaxial rheometer. We consider axial flow of Herschel Bulkley mode1 between two concentric cylinders with the inner one rotating, while the outer cylinder is held stationary. An attempt has been made to direct the...

متن کامل

Rheological properties of blood after whole body gamma-irradiation

Background: The study of rheological properties of blood has special interest since it is a circulating fluid exposed to shear rates during its life time. This work aims to investigate the influence of whole body gamma irradiation on the rheological properties of rat’s blood. The applied shear rate was from 12 to 375 s-1. Low shear viscosity (up to 100 s-1) depends mainly on the erythroc...

متن کامل

Entropy generation analysis of non-newtonian fluid in rotational flow

The entropy generation analysis of non-Newtonian fluid in rotational flow between two concentric cylinders is examined when the outer cylinder is fixed and the inner cylinder is revolved with a constant angular speed. The viscosity of non-Newtonian fluid is considered at the same time interdependent on temperature and shear rate. The Nahme law and Carreau equation are used to modeling dependenc...

متن کامل

Effect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery

A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005