Characterization of a pressure measuring system for the evaluation of medical devices.
نویسندگان
چکیده
The purpose of this study is to evaluate the possible use of four "FSA" thin and flexible resistive pressure mapping systems, designed by Vista Medical (Winnipeg, Manitoba, Canada), for the measurement of interface pressure exerted by lumbar belts onto the trunk. These sensors were originally designed for the measurement of low pressure applied by medical devices on the skin. Two types of tests were performed: standard metrology tests such as linearity, hysteresis, repeatability, reproducibility and drift, and specific tests for this application such as curvature, surface condition and mapping system superposition. The linear regression coefficient is between 0.86 and 0.98; hysteresis is between 6.29% and 9.41%. Measurements are repeatable. The location, time and operator, measurement surface condition and mapping system superposition have a statistically significant influence on the results. A stable measure is verified over the period defined in the calibration procedure, but unacceptable drift is observed afterward. The measurement stays suitable on a curved surface for an applied pressure above 50 mmHg. To conclude, the sensor has acceptable linearity, hysteresis and repeatability. Calibration must be adapted to avoid drift. Moreover, when comparing different measurements with this sensor, the location, the time, the operator and the measurement surface condition should not change; the mapping system must not be superimposed.
منابع مشابه
Impact of Measuring Devices and Data Analysis on the Determination of Gas Membrane Properties
The time-lag method, using a gas permeation experiment, is currently the most popular method for determining the membrane properties: diffusivity coefcient and permeability coefcient, and from which the solubility coefcient can be calculated. In this investigation, the impact of systematic, random (noise), resolution and extrapolation errors associated with gas permeatio...
متن کاملEvaluation of the Portal Imaging System Performance for an Elekta Precise Linac in Radiotherapy
Introduction: Electronic portal imaging devices (EPIDs) provide two- and three-dimensional planar and volumetric cone beam images to improve the accuracy of radiation treatment delivery. Periodic quality assurance (QA) of EPIDs is essential for dosimetric verification in radiotherapy. In this study, a QA program was implemented to evaluate the function of the EPID to be confident in applying co...
متن کاملComparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries
Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...
متن کاملEvaluation of noise pollution in Parks of Sanandaj City and zoning with Geographic Information System
It is accepted that noise pollution has a major impact on health, such as physical, physiological, psychological and performance related effects, all over the world. This study aims to evaluate noise pollution in four urban parks located in Sanandaj City, Iran and to zone it in GIS environment. Sound pressure level (SPL) and maximum sound level (Lmax) were measured at 45 points (each point was ...
متن کاملFormulation Development and Evaluation of the Therapeutic Efficacy of Brinzolamide Containing Nanoemulsions
Brinzolamide (BZ) is an intraocular pressure reducing agent with low bioavailability. The purpose of the present study was to overcome this issue by development of BZ containing nanoemulsions (NEs) as an ocular drug delivery system with desirable therapeutic efficacy. Brinzolamide NEs were prepared by the spontaneous emulsification method. Based on initial release studies, twelve formulations w...
متن کاملFormulation Development and Evaluation of the Therapeutic Efficacy of Brinzolamide Containing Nanoemulsions
Brinzolamide (BZ) is an intraocular pressure reducing agent with low bioavailability. The purpose of the present study was to overcome this issue by development of BZ containing nanoemulsions (NEs) as an ocular drug delivery system with desirable therapeutic efficacy. Brinzolamide NEs were prepared by the spontaneous emulsification method. Based on initial release studies, twelve formulations w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 228 12 شماره
صفحات -
تاریخ انتشار 2014