Dosimetric perturbation from cloth and paper gowns for total skin electron irradiation
نویسندگان
چکیده
Traditionally, total skin electron patients remove all clothing for treatment. It is generally assumed that this is best for the treatment of superficial skin lesions out of concern clothing may significantly perturb dose. We investigate the dosimetric effect of patient gowns and determine the necessity of treating patients naked. Using GAFCHROMIC EBT2 film, dose to a cylindrical phantom was measured with cloth, paper, and tri-layer cloth gowns, compared to no covering. A 6 MeV electron beam with spoiler accessory was used at ~ 4 meters source-to-skin distance. The gantry was angled at 248° and 292°. The phantom was rotated at -60°, 0°, and 60° relative to the beam's central axis, simulating the Stanford technique. This was also repeated for films sandwiched between the phantom's discs. Using a Markus chamber, the effect of air gaps of 0 to 5 cm in cloth and paper gowns was measured. The water equivalent attenuation of the gowns was determined through transmission studies. Compared to no covering, films placed on the phantom surface revealed an average increase of 0.8% in dose for cloth, 1.8% for tri-layered cloth, and 0.7% for paper. Films sandwiched within the phantom showed only slight shift of the percent depth-dose curves. Markus chamber readings revealed 1.4% for tri-layered cloth, and < 0.2% for single layer cloth or paper. Air gaps appeared to have a minimal effect. Transmission measurements found that one layer of cloth is equal to 0.2mm of solid water. Cloth and paper gowns appear to slightly increase the dose to the skin, but will not introduce any significant dose perturbation (<1%). Gowns having folds and extra layers will have a small additional perturbation (<2%). To minimize perturbation, one should smooth out any folds or remove any pockets that form extra layers on the gown.
منابع مشابه
A dosimetric study of deep skin electron therapy with overlapping stationary radiation fields – A case report
Background: For radiotherapy of total skin including sub-cutaneous tissue up to a depth of 3 cm on the entire left leg of an adult (Angiosarcoma skin), a complex treatment with multiple stationary electron fields was planned at our clinic. The details of dosimetry, clinical dose measurements are presented. Materials and Methods: The treatment planned with 6 overlapping 9 MeV electron fields in ...
متن کاملFabrication of anthropomorphic phantoms for use in total body photon irradiation and total skin electron irradiation studies
Introduction: Total Skin Electron Therapy (TSET) and Total Body Irradiation (TBI) are kinds of treatment which use electron and photon beams to treat special types of cancers. The aim of these techniques are to deliver uniform dose to the entire skin while minimizing delivered dose to organs at risk. To check the homogeneity of dose delivery in TBI and TSET, using a humanoid ph...
متن کاملDosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam
Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradiation in post‑lump...
متن کاملComparison of two radiation techniques in breast boost delivery
Introduction: In the treatment of breast cancer, breast conserving surgery (BCS) and whole breast irradiation is a usual technique. The influence of lumpectomy boost following breast radiotherapy is apparent, but there are different delivery methods. This work intended to compare the dosimetric parameters of electron beams and photon beams for boosting irradiation in breast can...
متن کاملTotal skin electron therapy (TSET): Monte Carlo Simulation and implementation
Introduction: Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Operating procedures for total skin electron irradiation and its dosimetry vary in different radiation therapy centers in the world. In this article, validation of TSET techniq...
متن کامل