Fractures of the thoracic spine in patients with minor trauma: comparison of diagnostic accuracy and dose of biplane radiography and MDCT.

نویسندگان

  • M Karul
  • P Bannas
  • B P Schoennagel
  • A Hoffmann
  • U Wedegaertner
  • G Adam
  • J Yamamura
چکیده

OBJECTIVES To investigate the accuracy of biplane radiography in the detection of fractures of the thoracic spine in patients with minor trauma using multidetector computed tomography (MDCT) as the reference and to compare the dose of both techniques. METHODS 107 consecutive trauma patients with suspected fractures of the thoracic spine on physical examination were included. All had undergone biplane radiography first, followed by a MDCT scan between October 2008 and October 2012. A fourfold table was used for the classification of the screening test results. Both the Chi-square test (χ(2)) and the mean dose-length product (DLP) were used to compare the diagnostic methods. RESULTS MDCT revealed 77 fractures in 65/107 patients (60.7%). Biplane radiography was true positive in 32/107 patients (29.9%), false positive in 19/107 patients (17.8%), true negative in 23/107 (21.5%) and false negative in 33/107 patients (30.8%), showing a sensitivity of 49.2%, a specificity of 54.7%, a positive predictive value (PPV) of 62.7%, a negative predictive value (NPV) of 41.1%, and an accuracy of 51.4%. The presence of a fracture on biplane radiography was highly statistical significant, if this was simultaneously proven by MDCT (χ(2)=7.6; p=0.01). None of the fractures missed on biplane radiography was unstable. The mean DLP on biplane radiography was 14.5mGycm (range 1.9-97.8) and on MDCT 374.6mGycm (range 80.2-871). CONCLUSIONS The sensitivity and the specificity of biplane radiography in the diagnosis of fractures of the thoracic spine in patients with minor trauma are low. Considering the wide availability of MDCT that is usually necessary for taking significant therapeutic steps, the indication for biplane radiography should be very restrictive.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

ارزیابی دز ورودی پوستی و دز مؤثر بیماران در معمول ترین آزمون های رادیولوژی

Introduction: Nowadays, we are witnessing a progressive application of radiology techniques in various communities as well as in Iran. Medical radiological examinations are one of the important sources of public radiological dose. Entrance skin doses and effective doses for patients in diagnostic radiology examinations should be assessed for the imaging techniques optimization and patient&rsquo...

متن کامل

Paediatric Dose AssessmentToward Establishment of National Diagnostic Reference Levels for Digital Radiography Examinations in Iran

Introduction: Paediatric patients deserve special attention because of the higher radiation risks compared with adults. The main purpose of this study is to determine patient dose and diagnostic reference level for Paediatric through Entrance Surface Dose (ESD) calculations in common X-ray examination and to establish Paediatric national DRLs in digital radiography in Iran. <...

متن کامل

Evaluation of Ultrasonography in Diagnosis of Nasal Fracture and Compared it with Plain Radiography in Dogs

Objective- One of the important causes of nasal fracture is a trauma that can be diagnosed in clinical examinations and diagnostic imaging but it should be noted that radiography may show false fractures in the nose. This study evaluates the value of ultrasonography in the diagnosis of nasal fractures and compared it with plain radiography. Design- Retrospective study. Animals- 12 d...

متن کامل

Comparison of the Diagnostic Accuracy of Digital Intraoral Radiography with PSP and CBCT in the Detection of Horizontal and Vertical Dental Root Fractures

Background and Aim: Clinical and radiographic diagnoses of dental root fractures have always been difficult and require high accuracy in dental care and treatment. The aim of this study was to compare the diagnostic accuracy of intraoral digital radiography (PSP) and CBCT in the detection of horizontal and vertical root fractures (HRF and VRF). Materials and Methods: For this experimental stud...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of radiology

دوره 82 8  شماره 

صفحات  -

تاریخ انتشار 2013