Development and Validation of a High-Performance Liquid Chromatography Method With UV Detection for Determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) Biuret in Rat Plasma
نویسندگان
چکیده
BACKGROUND Recently, biuret derivatives have been reported as showing moderate to good cytotoxic effect against certain cancer cell lines. In this study, a high-performance liquid chromatography method was developed for determination of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret (PEQB) in rat plasma to use in future studies on this compound and related derivatives. OBJECTIVES In this study, we describe a simple and sensitive high-performance liquid chromatography method with UV detection for determination of 1-(2-phenylethyl)-6-(quinaldin-4-yl) biuret (PEQB) in rat plasma. MATERIALS AND METHODS Separations were performed on a Nucleosil-100 CN HPLC column (125 × 4.0 mm) (5 µm), using a mixture of acetonitrile: methanol: potassium dihydrogen phosphate buffer (0.05 M, pH 3.5) (10:10:80) as mobile phase delivered at a flow rate of 1 mL/minute. Detection of PEQB and internal standard (1-([[3-(1,3-benzothiazol-2-ylsulfanyl)propyl]carbamoyl]amino)-N-phenylformamide) was performed at 235 nm and ambient temperature. Plasma samples (200 µL) were prepared by addition of 40 µL internal standard (100 µg/mL), and 400 µL acetonitrile. After vortex mixing and centrifugation at 10000 g, 50 µL of the clear supernatant was directly injected onto the chromatography column. Calibration curves were constructed by fitting the peak area ratio of the biuret to internal standard against concentration of biuret to a power model using generalized least squares nonlinear regression method. RESULTS Under the above chromatography condition, biuret compound (PEQB) and the internal standard were detected at 4.5 and 13.5 minutes, respectively. Limit of quantitation of the PEQB was 0.1 µg/mL. Accuracy of the method over the concentration range of 0.1-100 µg/mL was between 88-109%. Inter- and intraday precisions were 4-19% and 6-8%, respectively. A good relationship in the form of a power model was found for two separate concentration ranges of 0.1-1 and 2.5-100 µg/mL (R (2)> 0.99). CONCLUSIONS The presented simple HPLC method is sufficiently accurate, precise and sensitive for the quantitation of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret in rat plasma.
منابع مشابه
Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملSimple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملDevelopment of a Simple and Efficient Method for Preconcentration and Determination of Trace Levels of Fexofenadine in Plasma and Urine Samples
A simple, inexpensive and sensitive three-phase hollow fiber liquid-phase microextraction (HFLPME) coupled with high performance liquid chromatography (HPLC) with UV detection was successfully developed for determination of trace level of an anti-Histamine drug, fexofenadine, in human plasma and urine. The analyte was extracted into n-octanol that was immobilized in the wall of a porous hollow ...
متن کاملDevelopment and Validation of a HPLC Method for Determination of Pefloxacin in Tablet and Human Plasma
Objective(s) Developing and validating a simple, efficient, reproducible and economic reversed phase high performance liquid chromatographic (RP-HPLC) method for the quantitative determination of pefloxacin in bulk material, tablets and in human plasma. Materials and Methods A shim-pack CLC-ODS column and a mobile phase constituting acetonitrile: 0.025 M phosphoric acid solution (13:87 v/v, ...
متن کاملDevelopment and validation of a HPLC-UV method for determination of Proscillaridin A in Drimia maritima
Background and objectives:Drimia maritima (L.) Stearn also known as squill is a medicinally important plant that has been used for various ailments such as dropsy, respiratory disorders, jaundice and epilepsy from ancient times. Proscillaridin A is identified as one of the most effective compounds in the plant with remarkable pharmacological features including efficacy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2013