Bladder (ICRU) dose point does not predict urinary acute toxicity in adjuvant isolated vaginal vault high-dose-rate brachytherapy for intermediate-risk endometrial cancer
نویسندگان
چکیده
PURPOSE High-dose-rate brachytherapy (HDR-BT) alone is an adjuvant treatment option for stage I intermediaterisk endometrial cancer after complete surgical resection. The aim of this study was to determine the value of the dose reported to ICRU bladder point in predicting acute urinary toxicity. Oncologic results are also presented. MATERIAL AND METHODS One hundred twenty-six patients were treated with postoperative HDR-BT 24 Gy (4 × 6 Gy) per ICRU guidelines for dose reporting. Cox analysis was used to identify variables that affected local control. The mean bladder point dose was examined for its ability to predict acute urinary toxicity. RESULTS Two patients (1.6%) developed grade 1 gastrointestinal toxicity and 12 patients (9.5%) developed grades 1-2 urinary toxicity. No grade 3 or greater toxicity was observed. The mean bladder point dose was 46.9% (11.256 Gy) and 49.8% (11.952 Gy) for the asymptomatic and symptomatic groups, respectively (p = 0.69). After a median follow-up of 36.8 months, the 3-year local failure and 5-year cancer-specific and overall survival rates were 2.1%, 100%, and 94.6%, respectively. No pelvic failure was seen in this cohort. Age over 60 years (p = 0.48), lymphatic invasion (p = 0.77), FIGO histological grade (p = 0.76), isthmus invasion (p = 0.68), and applicator type (cylinder × ovoid) (p = 0.82) did not significantly affect local control. CONCLUSIONS In this retrospective study, ICRU bladder point did not correlate with urinary toxicity. Four fractions of 6 Gy HDR-BT effected satisfactory local control, with acceptable urinary and gastrointestinal toxicity.
منابع مشابه
An analysis of simulation for adjuvant intracavitary high-dose-rate brachytherapy in early-stage endometrial cancer.
PURPOSE The utility of serial simulations in vaginal vault irradiation is controversial. Our primary endpoint was to assess the significance of simulation in women who received adjuvant intracavitary high-dose-rate brachytherapy (HDR-BT) for early-stage endometrial adenocarcinoma. Secondary endpoints included assessment of acute and late treatment toxicity, medication requirements, and charges ...
متن کاملBladder and rectum dose estimations on digitized radiographs for vaginal brachytherapy after hysterectomy
The purpose of this study was to evaluate the feasibility of assessing bladder and rectal point doses, using orthogonal radiographs without treatment planning, for vaginal cylinder applicator (VC), high-dose-rate (HDR) vaginal cuff brachytherapy (BT) after hysterectomy. Thirty-three VC HDR BT treatment plans from 31 postop- erative endometrial cancer patients were retrospectively analyzed. Sing...
متن کاملDosimetry and toxicity outcomes in postoperative high-dose-rate intracavitary brachytherapy for endometrial carcinoma
PURPOSE The optimal dosimetric parameters and planning techniques for high-dose-rate vaginal brachytherapy (HDR-VB) are unclear. Our aim was to evaluate the utility of bladder and rectal dosimetry for patients receiving HDR-VB for postoperative treatment of endometrial carcinoma. MATERIAL AND METHODS Patients with endometrial cancer who underwent postoperative HDR-VB from January 1, 2004 thro...
متن کاملEffects of bladder distension on dose distribution of vaginal vault brachytherapy in patients with endometrial cancer
PURPOSE To investigate dosimetric effects of bladder distention on organs at risk (OARs) during treatment of endometrial cancer using 3D image-based planning of postoperative vaginal vault brachytherapy (BRT). MATERIAL AND METHODS Fifteen patients with early-stage endometrial cancer were studied, each undergoing adjuvant BRT of vaginal vault via 3.5 cm diameter cylinder. As treatment, 25 Gy i...
متن کاملVolumetric (3D) bladder dose parameters are more reproducible than point (2D) dose parameters in vaginal vault high-dose-rate brachytherapy
There is no consensus on the use of computed tomography in vaginal cuff brachytherapy (VCB) planning. The purpose of this study was to prospectively determine the reproducibility of point bladder dose parameters (DICRU and maximum dose), compared with volumetric-based parameters. Twenty-two patients who were treated with high-dose-rate (HDR) VCB underwent simulation by computed tomography (CT-s...
متن کامل