Horseradish Peroxidase (HRP) Immobilized Poly(aniline-co-m-aminophenol) Film Electrodes–fabrication and Evaluation as Hydrogen Peroxide Sensor
نویسندگان
چکیده
Enzyme modified electrodes were fabricated with poly(aniline-co-maminophenol). Electrochemical polymerization of aniline and m-aminophenol was performed to get the film of copolymer on the surface of gold electrode. Modified electrodes were fabricated by two methods, physical entrapment and covalent cross-linking. In one of the method, gold nanoparticles were loaded into the copolymer film and horseradish peroxidase (HRP) was immobilized into the Au nanoparticle loaded copolymer film through physical entrapment. In the other method, the amino and -OH groups in the copolymer are utilized to form covalent functionalization with HRP via glutaric dialdehyde as cross-linker/mediator. The conducting copolymer/enzyme modified electrodes prepared by physical entrapment/covalent functionalization of enzyme were tested for electrocatalytic activities towards sensing of H2O2. Amperometric results indicate that enzyme modified electrode via physical entrapment possesses better electrocatalytic performance over covalent functionalized enzyme electrode.
منابع مشابه
Novel hydrogen peroxide sensors based on peroxidase-carrying poly[pyrrole-co-[4-(3-pyrrolyl)butanesulfonate]] copolymer films.
Amperometric hydrogen peroxide biosensors were fabricated by incorporating horseradish peroxidase (HRP) into poly[pyrrole-co-[4-(3-pyrrolyl)butanesulfonate]] (Py-PS) copolymer films deposited on an SnO2 electrode surface by electropolymerization. The HRP/Py-PS electrodes exhibited an extended dynamic range and a markedly improved operational and storage stability, compared with HRP-incorporated...
متن کاملEffects of fabrication parameters on the enzyme loading and sensor response of enzyme-carrying conductive polymer electrodes.
Hydrogen peroxide sensors where horseradish peroxidase (HRP) is incorporated into pyrrole/3-alkylsulfonate pyrrole copolymer films deposited on an SnO2 electrode (HRP/Py-PS electrode) were investigated with regard to the effects of the fabrication parameters (electropolymerization charge, deposition current density, and electrodeposition solution pH) on the amount of surface-immobilized enzyme ...
متن کاملDevelopment of Amperometric Hydrogen Peroxide Sensor Based on Horseradish Peroxidase-Immobilized Poly(Thiophene-co-EpoxyThiophene)
A modified electrode for hydrogen peroxide (H₂O₂) sensing was prepared via thiophene (Th) with epoxy group. Thiophene (EpoxyTh) with epoxy group was synthesized by reaction of 3-bromothiophene and glycidyl methacrylate (GMA) in acetonitrile according to Heck Reaction. The electrocopolymerization of Th and EpoxyTh was performed on the surface of indium tin oxide (ITO) electrode by cycling the po...
متن کاملFabrication of a hydrogen peroxide biosensor based on a self-assemble composite oxide film.
A titania film with horseradish peroxidase (HRP) was immobilized on indium tin oxide (ITO) electrodes to act as a biosensor of hydrogen peroxide via the self-assembling and sol-gel route. The film was characterized by the atomic functional microscopy, electrochemical and UV-vis spectroscopy methods. The resulting biosensor exhibited fast amperometric response and good stability to hydrogen pero...
متن کاملPeroxide-Dependent Analyte Conversion by the Heme Prosthetic Group, the Heme Peptide “Microperoxidase-11” and Cytochrome c on Chitosan Capped Gold Nanoparticles Modified Electrodes
In view of the role ascribed to the peroxidatic activity of degradation products of cytochrome c (cyt c) in the processes of apoptosis, we investigate the catalytic potential of heme and of the cyt c derived heme peptide MP-11 to catalyse the cathodic reduction of hydrogen peroxide and to oxidize aromatic compounds. In order to check whether cyt c has an enzymatic activity in the native state w...
متن کامل