Chemical Stability of Telavancin in Elastomeric Pumps☆
نویسندگان
چکیده
BACKGROUND VIBATIV is a once-daily, injectable lipoglycopeptide antibiotic approved in the U.S. for the treatment of hospital-acquired and ventilator-associated bacterial pneumonia (HABP/VABP) caused by susceptible isolates of Staphylococcus aureus when alternative treatments are not suitable. In addition, VIBATIV is approved in the U.S. for the treatment of adult patients with complicated skin & skin structure infections (cSSSI) caused by susceptible isolates of Gram-positive bacteria, including Staphylococcus aureus, both methicillin-susceptible (MSSA) and methicillin-resistant (MRSA) strains. OBJECTIVE To evaluate the chemical stability of telavancin (Vibativ; Theravance Biopharma US, Inc, Northbrook, Illinois), a lipoglycopeptide antibiotic with activity against methicillin-resistant Staphylococcus aureus, in 2 types of elastomeric pumps, the Intermate Infusion System (Baxter International Inc) and the Homepump Eclipse (I-Flow Corporation). METHODS Different sizes of the Baxter (Ontario, Canada) (105 mL and 275 mL) and I-Flow (Stoughton, Massachusetts) (100 mL and 250 mL) pumps were compared with glass controls. The telavancin drug product was reconstituted and diluted to concentrations of 0.6 mg/mL and 8.0 mg/mL using either 0.9% saline, 5% dextrose in water, or sterilized water for injection (0.6 mg/mL telavancin) or saline (8.0 mg/mL telavancin) followed by Ringer's Lactate solution. Pumps were filled and stored at 2°C to 8°C, protected from light. Aliquots from both pump types and for all telavancin reconstitution/dilution schemes and concentrations were taken over a period of 8 days and analyzed for appearance, pH, telavancin concentration and purity, and degradation products. RESULTS The pH of all pump solutions remained consistent throughout the 8-day analysis period, within a range of 4.6 to 5.7 for the 0.6 mg/mL and 4.4 to 4.9 for the 8.0 mg/mL telavancin solutions. There was no significant change in the chromatographic purity for any of the pump solutions examined. All decreases in telavancin concentration were ≤2.7%. Comparison of each test sample solution to the corresponding glass control indicated no loss of active drug due to absorption by the elastomeric material of the pumps. The greatest increase in the amount of total degradants observed over the 8-day period was ~0.7 w/w%. CONCLUSIONS The results of this study indicate that telavancin remains chemically stable when diluted in the Intermate Infusion System and the Homepump Eclipse elastomeric pumps and stored at 2°C to 8°C for up to 8 days protected from light at the concentration range and dilution schemes evaluated.
منابع مشابه
Chemical Stability of Ceftolozane/Tazobactam in Polyvinylchloride Bags and Elastomeric Pumps
BACKGROUND Elastomeric pumps are often used to administer intravenous antibiotics in the outpatient setting, but effective infusion requires that the drug remain stable in solution throughout the procedure. OBJECTIVE To determine the chemical stability of ceftolozane/tazobactam when reconstituted and stored over an extended time in the AccuFlo (EMED Technologies, El Dorado Hills, California) ...
متن کاملPost-reconstitution Stability of Telavancin with Commonly Used Diluents and Intravenous Infusion Solutions
OBJECTIVE The post-reconstitution chemical stability and microbial challenge hold time of nonpreserved telavancin for injection was determined using common reconstitution diluents and intravenous (IV) infusion solutions stored at room temperature with light (ambient) or at 2°C to 8°C without light (refrigeration). METHODS Telavancin was reconstituted with 5% dextrose, 0.9% normal saline, or s...
متن کاملThe flow Rate Accuracy of Elastomeric Infusion Pumps After Repeated Filling
BACKGROUND One of the frequent applications of elastomeric infusion pumps is postoperative pain management. In daily practice, the disposable pumps get refilled with modified medication combinations in the successive days; although, the accuracy of infusion rates is unknown to clinicians. OBJECTIVES Our aim was to evaluate the effect of repeated filling on the delivery rate accuracy of an ela...
متن کاملLong Term Stability Evaluation of Prostacyclin Released from Biomedical Device Through Turbiscan Lab Expert
Therapeutic guidelines indicate prostacyclin as the first line of treatment in inflammation and vascular diseases. Prostacyclins prevent formation of the platelet plug involved in primary hemostasis by inhibiting platelet activation and, combined with thromboxane, are effective vasodilators in vascular damage. Trans-Atlantic Inter-Society Consensus Document on Management of Peripheral Arterial ...
متن کاملAnalysis of Flow Rate Through Elastomeric Local Infiltration Analgesia Pumps
Background: Local infiltration analgesia pumps have been increasingly used to provide postoperative pain relief. However, their flow rate over time may not be reliable and accurate which can pose concerns regarding the achievement of the desired therapeutic level. We sought to find out in vitro if the flow rate of two elastomeric infusion pumps when combined with two types of wound catheter is ...
متن کامل