Acoustic measurements in a tissue mimicking liquid.

نویسندگان

  • M C Macdonald
  • E L Madsen
چکیده

A liquid has been developed that mimics soft tissue in terms of propagation speed, attenuation, and nonlinearity parameter B/A. Since the slope of the attenuation coefficient is nearly constant up to at least 18 MHz and the value can be anywhere in the range 0.1 through 0.7 dB/(cm MHz), the material is ideal for assessing the effectiveness of attenuation derating of output acoustic intensities and pressures measured in water. A clinical ultrasound system was used to transmit into the tissue mimicking liquid. The pulse intensity integral and rarefactional pressure at various field locations in the tissue mimicking liquid were computed and compared to the corresponding values measured in water with attenuation derating applied. The slope of the attenuation coefficient in the tissue mimicking liquid was used for the derating. From this data it is seen that the present practice of modeling in vivo exposure using linearly derated measurements made in water is not always conservative.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An exposimetry system using tissue-mimicking liquid.

Acoustic output measurements of diagnostic ultrasound scanners are currently performed in water and derated to approximate in situ values. The derating scheme ignores nonlinear propagation of sound waves and has been shown in previous numerical and experimental studies to tend to underestimate relevant pressure and intensity values in tissue mimicking media. This work describes an alternative m...

متن کامل

Acoustic resolution photoacoustic Doppler velocimetry in blood-mimicking fluids

Photoacoustic Doppler velocimetry provides a major opportunity to overcome limitations of existing blood flow measuring methods. By enabling measurements with high spatial resolution several millimetres deep in tissue, it could probe microvascular blood flow abnormalities characteristic of many different diseases. Although previous work has demonstrated feasibility in solid phantoms, measuremen...

متن کامل

Tissue-mimicking liquid for use in exposimetry.

OBJECTIVE Current determinations of diagnostic ultrasound exposure parameters (eg, peak rarefactional pressure and pulse intensity integral) are intended to correspond to propagation through soft tissue with a propagation speed of 1540 m/s and attenuation of 0.3 dB x cm(-1) x MHz(-1). These current measurements are made in water, which has very little attenuation, and a linear derating factor i...

متن کامل

Tissue-mimicking phantoms for photoacoustic and ultrasonic imaging

In both photoacoustic (PA) and ultrasonic (US) imaging, overall image quality is influenced by the optical and acoustical properties of the medium. Consequently, with the increased use of combined PA and US (PAUS) imaging in preclinical and clinical applications, the ability to provide phantoms that are capable of mimicking desired properties of soft tissues is critical. To this end, gelatin-ba...

متن کامل

Tuning acoustic and mechanical properties of materials for ultrasound phantoms and smart substrates for cell cultures.

Materials with tailored acoustic properties are of great interest for both the development of tissue-mimicking phantoms for ultrasound tests and smart scaffolds for ultrasound mediated tissue engineering and regenerative medicine. In this study, we assessed the acoustic properties (speed of sound, acoustic impedance and attenuation coefficient) of three different materials (agarose, polyacrylam...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine

دوره 18 1  شماره 

صفحات  -

تاریخ انتشار 1999