Heat production during prosthetic preparation of a one-piece dental implant.

نویسندگان

  • Eran Gabay
  • Omer Cohen
  • Eli E Machtei
چکیده

PURPOSE Preparation of a one-piece dental implant abutment is often needed to achieve a proper emergence profile for a definitive restoration. However, this procedure may compromise osseointegration through the production of heat. The aim of this study was to measure heat production during implant abutment preparation with different volumes of water irrigation using a one-piece implant system. MATERIALS AND METHODS Forty-five one-piece dental implants were used in this study. The implants were divided into three groups according to the water flow rate used during abutment preparation: 30 mL/min (G30), 15 mL/min (G15), and without water irrigation (G0). Thermocouples were positioned at the most coronal and most apical threads. The abutments were prepared using a high-speed dental handpiece. Preparation continued for 120 seconds or until the implant temperature reached 47°C. RESULTS The time needed to reach 47°C in the most coronal thread of group G0 was 5.73 ± 1.16 seconds. After the preparation was stopped at 47°C, the temperature continued to increase until reaching a maximum temperature. None of the implants in the water irrigation groups reached 47°C. The time needed to reach maximum temperature was significantly shorter for group G0 than the groups with water irrigation. A strong positive correlation was found between coronal and apical recordings. CONCLUSION Prosthetic preparation of one-piece dental implants without irrigation induced a rapid increase in temperature. Water irrigation reduced heat production during abutment preparation in a dose-dependent manner.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cooling profile following prosthetic preparation of 1-piece dental implants.

The aim of this study was to evaluate the effect of water irrigation on heat dissipation kinetics following abutment preparation of 1-piece dental implants. UNO 1-piece dental implants were mounted on Plexiglas apparatus clamping the implant at the collar. T-type thermocouple was attached to the first thread of the implant and recorded thermal changes at 100 millisecond intervals. Implants were...

متن کامل

Evaluation of heat conduction in dental implants after exposure to hot beverages.

STATEMENT OF PROBLEM It is unknown if the consumption of hot beverages after implant placement poses a danger of overheating at the bone-implant interface. PURPOSE The purpose of this study was to investigate the effect of simulated consumption of hot beverages on the heat transfer to different dental implant types, implant sizes, and the presence of an interim restoration. MATERIAL AND MET...

متن کامل

Determining the prevalence of peri-implantitis in patients one year after prosthetic loading in Khorramabad in 2021

Background and Aims: Although dental implants have become a successful and predictable ong-term treatment for patients, not all implant treatments are necessarily successful and pre-implant diseases are spreading. The aim of this study was to determine the prevalence of peri-implantitis in patients one year after prosthetic loading in Khorramabad in 2021. Materials and Methods: In this cross-s...

متن کامل

A Comparison of Heat Generation in Different Depths of Implant Drilling Site with and without a Sleeve

Introduction: The purpose of this study was to compare the heat generated from different depths of an implant drilling site with and without a sleeve. Materials and methods: In this study, 60 cortical bone samples were used and a load of 2.0 kg was applied. rilling for implant surgery, we used a diameter of 4.3 mm and a normal sleeve. Heat was measured from 3 different depths(3,6, an...

متن کامل

Principles of Overdenture on One-piece Narrow Dental Implants in Patients with Different Patterns of Mandibular Ridge Resorption

PRINCIPLES OF OVERDENTURE ON ONE-PIECE NARROW DENTAL IMPLANTS IN PATIENTS WITH DIFFERENT PATTERNS OF MANDIBULAR RIDGE RESORPTION (Abstract). Aim: To highlight the particularities of mandibular overdenture on one-piece narrow dental implants in patients with two frequent and high-difficulty clinical situations, namely flat alveolar ridge (also known as severe ridge resorption, when mainly vertic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 2010