Clinical Experience with the M4 Ahmed Glaucoma Drainage Implant

نویسندگان

  • Ilya Sluch
  • Brett Gudgel
  • Justin Dvorak
  • Mary Anne Ahluwalia
  • Kai Ding
  • Steve Vold
  • Steven Sarkisian
چکیده

Aim To evaluate the safety and efficacy of the M4 (porous polyethylene plate) Ahmed Glaucoma Valve (AGV) drainage implant in a multicenter retrospective study. Materials and methods A retrospective chart review of medical records of patients who had undergone the M4 Ahmed valve was performed from January 2013 to April 2015. The primary outcome measure was surgical failure defined as: Less than a 20% reduction in baseline intraocular pressure (IOP) to last follow-up visit, final IOP less than 5 mm Hg or greater than 18 mm Hg, reoperation for glaucoma, or loss of light perception vision. All eyes not meeting the above criteria were defined as success. Results A total of 291 eyes met all study inclusion criteria. The average follow-up in the study was 6 months (±7.6 months) with 112 patients achieving 12-month follow-up (38.5%). 208 eyes (71.5%) met the study success criteria at final follow-up. No statistically significant spikes in postoperative IOP at 1 and 4 months were detected. The average preoperative IOP was 26.0 on an average of 2.8 medications. At 6 months, the average IOP dropped to 16.7 on 0.9 medications and stayed relatively stable at 15.8 on 1.2 medications at 12-month follow-up. Conclusion The M4 valve appears to have less of a hypertensive phase compared with the other Ahmed class valves with a similar safety profile. While 71.5% success rate was achieved at final follow-up, the failure rate steadily increased over time. Clinical significance While the M4 production has been discontinued, the porous design of the M4 may avoid a pressure spike in the Ahmed valve class and warrants future investigation for valve design.How to cite this article: Sluch I, Gudgel B, Dvorak J, Ahluwalia MA, Ding K, Vold S, Sarkisian S. Clinical Experience with the M4 Ahmed Glaucoma Drainage Implant. J Curr Glaucoma Pract 2017;11(3):92-96.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glaucoma drainage implants: a critical comparison of types.

PURPOSE OF REVIEW The purpose of this review is to critically compare the various glaucoma drainage implants in popular use. RECENT FINDINGS Glaucoma drainage implants are being increasingly utilized in the surgical management of glaucoma. Comparisons between the various drainage implants are difficult because most clinical data are derived from retrospective studies with different study popu...

متن کامل

Comparative study of the safety and efficacy of the Ahmed glaucoma valve model M4 (high density porous polyethylene) and the model S2 (polypropylene) in patients with neovascular glaucoma.

OBJECTIVE To prospectively evaluate the safety and efficacy of the Ahmed glaucoma valve model M4 (High density porous polyethylene plate; Medpor) compared with the model S2 (polypropylene plate). METHOD Mexican patients with neovascular glaucoma were randomly included for each group (M4 and S2). They were operated on using conventional techniques and creating a sub-episcleral tunnel to place ...

متن کامل

The Clinical Use of Ahmed Valve Implant as an Aqueous Shunt for Control of Uveitic Glaucoma in Dogs

Objective: Safety and efficacy of Ahmed glaucoma valve implantation for the management of uveitis induced glaucoma evaluated on the five dogs with uncontrollable glaucoma. Materials and Methods: Ahmed Glaucoma Valve (AGV®; New World Medical, Rancho Cucamonga, CA, USA) is a flow restrictive, nonobstructive self-regulating valve system. Preoperative ocular evaluation included direct ophthalmoscop...

متن کامل

Combined phacoemulsification and Ahmed valve glaucoma drainage implant: a retrospective case series.

PURPOSE To report on the efficacy and safety of combined phacoemulsification and an Ahmed valve glaucoma drainage implant with respect to visual acuity improvement, intraocular pressure (IOP) control, and requirement for antiglaucoma medication. METHODS A retrospective chart review was conducted of 41 eyes (31 patients) with coexisting visually significant cataracts and uncontrolled glaucoma ...

متن کامل

EYcacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma

Aims—To evaluate the eYcacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucomas. Methods—This retrospective study reviewed the final intraocular pressure, visual outcome, and incidence of complications in all patients with the Ahmed glaucoma valve implant performed at the Prince of Wales Hospital, Hong Kong, between June 1996 and November 1998. Results—A to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017