Development and validation of a rapid liquid chromatographic method for the determination of oxatomide and its related impurities.

نویسندگان

  • Laura Curtin Whelan
  • Michael Geary
  • Paul Sweetman
چکیده

A rapid liquid chromatographic method was developed for the determination of oxatomide in its finished active pharmaceutical ingredient form and in the presence of its process impurities. The method was developed on a sub 2 µm Hypersil Zorbax XDB C18 column (30 × 4.6 mm, i.d., 1.8 µm). The rapid method employed a gradient mobile phase consisting of solvent A: 0.01 M tetrabutylammonium hydrogen sulfate and 0.5% (w/v) ammonium acetate in water and solvent B: acetonitrile. A flow rate of 2 mL/min was employed with the diode-array detector set at 230 nm. The original method supplied by Janssen Pharmaceuticals Ltd was run on a Thermo Scientific octadecylsilyl silica gel C18 column (100 × 4.6 mm, i.d., 5 µm) with an analysis time of 20 min. The main aim was to substantially reduce the analysis time while maintaining good efficiency. Run-time was reduced to 6.5 min with a total loss in analysis time of 68%. Solvent consumption was also reduced by 68%. Validation according to the International Conference of Harmonization guidelines was undertaken. The parameters examined were accuracy, precision, linearity, selectivity, robustness, limit of detection and limit of quantification; all criteria were met. Sample stability testing was also carried out. Oxatomide proved stable under ambient and 4°C temperatures and in the presence of light for up to 24 h.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

Determination of Synthetic Precursors as Impurities in Diclofenac Sodium Raw Material

Impurities of drug substances may produce some side effects in patient. Diclofenac Na is a member of non-steroidal anti inflammatory drugs (NSAIDs) family, which is routinely used by patients for the treatment of rheumatoid arthritis and various pains. To develop a method for the determination of synthetic precursors which could be remained as impurities in raw drug materials, Na diclofenac pow...

متن کامل

Determination of Synthetic Precursors as Impurities in Diclofenac Sodium Raw Material

Impurities of drug substances may produce some side effects in patient. Diclofenac Na is a member of non-steroidal anti inflammatory drugs (NSAIDs) family, which is routinely used by patients for the treatment of rheumatoid arthritis and various pains. To develop a method for the determination of synthetic precursors which could be remained as impurities in raw drug materials, Na diclofenac pow...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 52 10  شماره 

صفحات  -

تاریخ انتشار 2014