Signal-averaged P wave analysis for delineation of interatrial conduction – Further validation of the method

نویسندگان

  • Fredrik Holmqvist
  • Pyotr G Platonov
  • Rasmus Havmöller
  • Jonas Carlson
چکیده

BACKGROUND The study was designed to investigate the effect of different measuring methodologies on the estimation of P wave duration. The recording length required to ensure reproducibility in unfiltered, signal-averaged P wave analysis was also investigated. An algorithm for automated classification was designed and its reproducibility of manual P wave morphology classification investigated. METHODS Twelve-lead ECG recordings (1 kHz sampling frequency, 0.625 microV resolution) from 131 healthy subjects were used. Orthogonal leads were derived using the inverse Dower transform. Magnification (100 times), baseline filtering (0.5 Hz high-pass and 50 Hz bandstop filters), signal averaging (10 seconds) and bandpass filtering (40-250 Hz) were used to investigate the effect of methodology on the estimated P wave duration. Unfiltered, signal averaged P wave analysis was performed to determine the required recording length (6 minutes to 10 s) and the reproducibility of the P wave morphology classification procedure. Manual classification was carried out by two experts on two separate occasions each. The performance of the automated classification algorithm was evaluated using the joint decision of the two experts (i.e., the consensus of the two experts). RESULTS The estimate of the P wave duration increased in each step as a result of magnification, baseline filtering and averaging (100 +/- 18 vs. 131 +/- 12 ms; P < 0.0001). The estimate of the duration of the bandpass-filtered P wave was dependent on the noise cut-off value: 119 +/- 15 ms (0.2 microV), 138 +/- 13 ms (0.1 microV) and 143 +/- 18 ms (0.05 microV). (P = 0.01 for all comparisons). The mean errors associated with the P wave morphology parameters were comparable in all segments analysed regardless of recording length (95% limits of agreement within 0 +/- 20% (mean +/- SD)). The results of the 6-min analyses were comparable to those obtained at the other recording lengths (6 min to 10 s). The intra-rater classification reproducibility was 96%, while the interrater reproducibility was 94%. The automated classification algorithm agreed with the manual classification in 90% of the cases. CONCLUSION The methodology used has profound effects on the estimation of P wave duration, and the method used must therefore be validated before any inferences can be made about P wave duration. This has implications in the interpretation of multiple studies where P wave duration is assessed, and conclusions with respect to normal values are drawn.P wave morphology and duration assessed using unfiltered, signal-averaged P wave analysis have high reproducibility, which is unaffected by the length of the recording. In the present study, the performance of the proposed automated classification algorithm, providing total reproducibility, showed excellent agreement with manually defined P wave morphologies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Signal-averaged P wave in patients with paroxysmal atrial fibrillation.

The theoretical and experimental rational of atrial signal-averaged ECG in patients with AF is delay in the intra-atrial and interatrial conduction. Similar to the ventricular signal-averaged ECG, the atrial signal-averaged ECG is an averaging of a high number of consecutive P waves that match the template created earlier P wave triggering is preferred over QRS triggering because of more accura...

متن کامل

The Effect of Bronchial Asthma on Interatrial Electromechanical Delay Coupling Obtained Using Tissue Doppler Imaging

Background: Asthma is a predisposing factor for the development of atrial fibrillation. Asthma disturbs the electrophysiology in the right and left atrium. The aim of this study was to evaluate atrial electromechanical delay by coupling obtained from tissue Doppler imaging (TDI) in children. Methods: A cross-sectional study was conducted on 50 patients with Bronchial Asthma, compared with 50 hea...

متن کامل

reviews Title : Unfiltered signal averaged P wave analysis - further validation of the method

Title: Unfiltered signal averaged P wave analysis-further validation of the method Authors:

متن کامل

Interatrial Block: A Virtual Pandemic Requiring Attention

Interatrial block (IAB) denotes a conduction delay between the two atria (P-wave duration ≥110 ms). Depending on the severity of the block, IAB can be partial or advanced. Even though several studies have reported a high prevalence of IAB, it still remains a diagnosis many neglect without any follow-up. The crisis in IAB is undramatic until predictable complications appear. Nevertheless, the da...

متن کامل

A Unified Framework for Delineation of Ambulatory Holter ECG Events via Analysis of a Multiple-Order Derivative Wavelet-Based Measure

In this study, a new long-duration holter electrocardiogram (ECG) major events detection-delineation algorithm is described which operates based on the false-alarm error bounded segmentation of a decision statistic with simple mathematical origin. To meet this end, first three-lead holter data is pre-processed by implementation of an appropriate bandpass finite-duration impulse response (FIR) f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BMC Cardiovascular Disorders

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2007