Rotation thromboelastometry (ROTEM) stability and reproducibility over time.

نویسندگان

  • Oliver Michel Theusinger
  • Johannes Nürnberg
  • Lars M Asmis
  • Burkhardt Seifert
  • Donat Rudolf Spahn
چکیده

BACKGROUND Thromboelastometry is a whole blood assay performed to evaluate the viscoelastic properties during blood clot formation and lysis. Rotation thromboelastography (ROTEM), Pentapharm GmbH, Munich, Germany) has overcome some of the limitations of classic thromboelastography. So far, no clinical validation on reproducibility (inter- and intra-assay variability) and sample stability over time has been published. METHODS To evaluate the pre-analytic aspects, sample stability over time was assessed in 48 patients in eight age groups. Citrated blood was stored at room temperature. Tests measured every 30 min from T 0 min up to T 120 min on two ROTEM devices were INTEM (ellagic acid activated intrinsic pathway), EXTEM (tissue factor-triggered extrinsic pathway) and FIBTEM (with platelet inhibitor (cytochalasin D) evaluating the contribution of fibrinogen to clot formation). Precision by intra- and inter-assay variability was evaluated at two points of time in 10 volunteers. Finally, reference intervals and effect of age and sex were evaluated. RESULTS Blood was stable over 120 min and no significant differences in ROTEM results were found. Maximum clot firmness measurements had a coefficient of variation of <3% for EXTEM, <5% for INTEM and <6% for FIBTEM. For clot formation time, the coefficient of variation was <4% for EXTEM and <3% for INTEM. Coefficient of variation for angle alpha was <3% for EXTEM and <6% for INTEM. The coefficient of variation for clotting time was <15% for both EXTEM and INTEM. Small but significant differences between ROTEM devices were found for maximum clot firmness in FIBTEM and INTEM as well as clot formation time and alpha angle in INTEM. CONCLUSIONS ROTEM yields stable results over 120 min with a minimal variability on the same ROTEM device. However, small but significant differences between ROTEM devices were observed. Analysis should be performed on the same ROTEM device if small differences are of importance for treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro factor XIII supplementation increases clot firmness in Rotation

Factor XIII (F XIII) is an essential parameter for final clot stability. The purpose of this study was to determine the impact of the addition of factor (F)XIII on clot stability as assessed by Rotation Thromboelastometry (ROTEM®). In 90 intensive care patients ROTEM® measurements were performed after in vitro addition of F XIII 0.32 IU, 0.63 IU, 1.25 IU and compared to diluent controls (DC; aq...

متن کامل

In vitro factor XIII supplementation increases clot firmness in Rotation Thromboelastometry (ROTEM).

Factor XIII (F XIII) is an essential parameter for final clot stability. The purpose of this study was to determine the impact of the addition of factor (F)XIII on clot stability as assessed by Rotation Thromboelastometry (ROTEM). In 90 intensive care patients ROTEM measurements were performed after in vitro addition of F XIII 0.32 IU, 0.63 IU, 1.25 IU and compared to diluent controls (DC; aqua...

متن کامل

Evaluation of recombinant factor VIII Fc (Eloctate) activity by thromboelastometry in a multicenter phase 3 clinical trial and correlation with bleeding phenotype

: The aim of this study was to compare the hemostatic efficacy of recombinant factor VIII Fc (rFVIIIFc) (Eloctate) and Advate by ex-vivo rotation thromboelastometry (ROTEM) of whole blood and to explore potential ROTEM parameters that may be more predictive of a patient's bleeding tendency than plasma FVIII activity. Thirteen clinical sites were selected to perform ROTEM on freshly collected bl...

متن کامل

Monitoring the hemostasis with rotation thromboelastometry in patients with acute STEMI on dual antiplatelet therapy

Rotation thromboelastometry (ROTEM) is a viscoelastometric point-of-care-test for the complex evaluation of changes in hemostasis, performed in whole blood. However, no prospective study evaluating the efficacy of the antiplatelet therapy using ROTEM was performed.Fifty-six patients (34 men, 22 women, mean age 67.75 years, and age range 34-88 years) with acute ST-elevation myocardial infarction...

متن کامل

Rotational thromboelastometry predicts thromboembolic complications after major non-cardiac surgery

INTRODUCTION Thromboembolic complications contribute substantially to perioperative morbidity and mortality. Routine laboratory tests do not detect patients with acquired or congenital hypercoagulability who may be at increased risk of perioperative thromboembolism. Rotational thromboelastometry (ROTEM) is a digitized modification of conventional thromboelastography that is stable and technical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2010