A review of microbial fuel cells coupled with constructed wetland
نویسندگان
چکیده
منابع مشابه
Treatment of Oil Wastewater and Electricity Generation by Integrating Constructed Wetland with Microbial Fuel Cell
Conventional oil sewage treatment methods can achieve satisfactory removal efficiency, but energy consumption problems during the process of oil sewage treatment are worth attention. The integration of a constructed wetland reactor and a microbial fuel cell reactor (CW-MFC) to treat oil-contaminated wastewater, compared with a microbial fuel cell reactor (MFC) alone and a constructed wetland re...
متن کاملConstructed Wetland Treatment Plant Constructed Wetland Microbial Fuel Cells
18 This work aimed at determining the amount of energy that can be harvested by 19 implementing microbial fuel cells (MFC) in horizontal subsurface constructed wetlands 20 (HSSF CWs) during the treatment of real domestic wastewater. To this aim, MFC were 21 implemented in a pilot plant based on two HSSF CW, one fed with primary settled 22 wastewater (Settler line) and the other fed with the eff...
متن کاملFeasibility study of simultaneous azo dye decolorization and bioelectricity generation by microbial fuel cell-coupled constructed wetland: substrate effects
Microbial fuel cells (MFCs) were embedded into constructed wetlands to form microbial fuel cell coupled constructed wetlands (CW-MFCs) and were used for simultaneous azo dye wastewater treatment and bioelectricity generation. For the first time, the effects of different substrate biomass on the performance of CW-MFCs were studied. Group A had the highest substrate biomass of 0.453 g VSS per L, ...
متن کاملOptimization of Bioelectricity Generation in Constructed Wetland-Coupled Microbial Fuel Cell Systems
Constructed wetland-coupled microbial fuel cell systems (CW-MFCs) incorporate an aerobic zone and an anaerobic zone to generate electricity that achieves the oxidative degradation of contaminants. However, there are few reports on the performance of such coupled systems. In this study, we determined the optimal configuration of CW-MFCs to characterize their electricity generation performance. B...
متن کاملEvaluation of the performance of conventional and baffled horizontal subsurface constructed wetland in the removal of Reactive Red 198
Background and Objective: Reactive Red 198 is a mono azo dye widely used in the textile industry of Iran. The toxicity of reactive dyes is higher than other dyes and causes disorders such as irritation, cancer and mutation in humans. The overall objective of this study was to determine the efficiency of a Constructed Wetland pilot system with conventional and baffled horizontal subsurface flow ...
متن کامل