Importance of renal function on prognostic value of cardiac iodine-123 metaiodobenzylguanidine scintigraphy.
نویسندگان
چکیده
OBJECTIVE Cardiac iodine-123 metaiodobenzylguanidine (MIBG) can be used to evaluate cardiac sympathetic nerve function and is useful for assessing the prognosis of patients with heart disease. Renal impairment in heart failure patients has been recognized as an independent risk factor for morbidity and mortality, and has been observed as abnormal uptake and washout of cardiac MIBG imaging. The purpose of this study was to evaluate the prognostic value of cardiac MIBG imaging in heart disease patients with a glomerular filtration rate (GFR) either > or = 60 ml/min/1.73 m2 or < 60 ml/min/1.73 m2. METHODS Heart disease patients (n: 135, male/female: 87/48, mean age: 63 years, coronary artery disease/dilated cardiomyopathy/myocarditis: 41/62/32, mean left ventricular ejection fraction: 51%, GFR > or = 60 ml/min/1.73 m2/ GFR < 60 ml/min/1.73 m2: 103/32) underwent cardiac MIBG imaging and were followed-up for 2.7 years. GFR was calculated by the Modification of Diet in Renal Disease (MDRD) equation. Cardiac MIBG imaging was obtained 15 min and 4 h after isotope injection. The parameters analyzed for cardiac MIBG imaging were the heart-to-mediastinum ratio (H/M) on the delayed planar image and the cardiac washout rate. RESULTS Cardiac death was observed in 9 of 103 patients (9%) with a GFR > or = 60 ml/min/1.73 m2 and in 6 of 32 patients (19%) with a GFR < 60 ml/min/1.73 m2. The mortality ratio tended to be higher in patients with a GFR < 60 ml/min/1.73 m2 than in patients with a GFR > or = 60 ml/min/1.73 m2 (p = 0.10 with Kaplan-Meier survival curves). In patients with a GFR > or = 60 ml/min/1.73 m2, Cox regression analysis showed that a delayed H/M < 146% was the most powerful predictor for cardiac death (Hazard ratio: 6.9, p = 0.014). However, in patients with a GFR < 60 ml/min/1.73 m2, the utility of cardiac MIBG imaging could not be proved. CONCLUSIONS A delayed H/M is a powerful predictor of cardiac death if the GFR is 60 ml/min/1.73 m2 or more.
منابع مشابه
Metaiodobenzylguanidine scintigraphy of cardiac sympathetic innervation.
Metaiodobenzylguanidine (MIBG), a noradrenaline analogue,labelled with radioactive iodine I-123 is used for assessing pre-synaptic activity of the myocardial adrenergic system. The paper describes the mechanism of myocardial I-123-MIBG uptake and the relevant examination methods. It also refers to the necessity of standardising acquisition methods and assessment criteria in order to improve com...
متن کاملUptake index of 123I-metaiodobenzylguanidine myocardial scintigraphy for diagnosing Lewy body disease
Objective(s): Iodine-123 metaiodobenzylguanidine (123I-MIBG) myocardial scintigraphy has been used to evaluate cardiac sympathetic denervation in Lewy body disease (LBD), including Parkinson’s disease (PD) and dementia with Lewy bodies (DLB). The heart-tomediastinum ratio (H/M) in PD and DLB is significantly lower than that in Parkinson’s plus syndromes and Alzheimer’s disease. Although this ra...
متن کاملCan combined assessment of baroreflex sensitivity and iodine-123 metaiodobenzylguanidine imaging be used for risk stratification of patients with type 2 diabetes mellitus?
he sympathetic nervous system of the heart is critically involved in the maintenance of cardiovascular homoeostasis by regulating cardiac contractility, conduction, heart frequency and peripheral vasoconstriction.1 It has been shown that a dysfunctional cardiac sympathetic nervous system exerts detrimental effects on the structural and functional integrity of the myocardium, leading to a marked...
متن کاملCardiac iodine-123 metaiodobenzylguanidine (123I-MIBG) scintigraphy parameter predicts cardiac and cerebrovascular events in type 2 diabetic patients without structural heart disease.
BACKGROUND Cardiac iodine-123 metaiodobenzylguanidine ((123)I-MIBG) scintigraphy is an established method of assessment of cardiovascular sympathetic function. The aim of the present study was to investigate the long-term cardiovascular predictive value of cardiac (123)I-MIBG scintigraphy parameters in Japanese type 2 diabetic patients without structural heart disease. METHODS AND RESULTS Car...
متن کاملIodine-123 metaiodobenzylguanidine scintigraphy in localising phaeochromocytomas--experience and meta-analysis.
BACKGROUND Recommendations on the use of I-123 metaiodobenzylguanidine (MIBG) scintigraphy in localising phaeochromocytomas vary. The accuracy of I-123 MIBG scintigraphy was determined by evaluating our own I-123 MIBG scans and performing a meta-analysis. MATERIALS AND METHODS Between January 1992 and May 2002, the I-123 MIBG scans of consecutive patients suspected of a phaeochromocytoma were...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of nuclear medicine
دوره 21 1 شماره
صفحات -
تاریخ انتشار 2007