Systematic Comparison of the Performance of Integrated Whole-Body PET/MR Imaging to Conventional PET/CT for ¹⁸F-FDG Brain Imaging in Patients Examined for Suspected Dementia.

نویسندگان

  • Stefan Hitz
  • Cornelia Habekost
  • Sebastian Fürst
  • Gaspar Delso
  • Stefan Förster
  • Sibylle Ziegler
  • Stephan G Nekolla
  • Michael Souvatzoglou
  • Ambros J Beer
  • Timo Grimmer
  • Matthias Eiber
  • Markus Schwaiger
  • Alexander Drzezga
چکیده

UNLABELLED Technologic specifications of recently introduced integrated PET/MR instrumentation, such as MR-based attenuation correction, may particularly affect brain imaging procedures. To evaluate the qualitative performance of PET/MR in clinical neuroimaging, we systematically compared results obtained with integrated PET/MR with conventional PET/CT in the same patients examined for assessment of cognitive impairment. METHODS Thirty patients underwent a single-injection ((18)F-FDG), dual-imaging protocol including PET/CT and integrated PET/MR imaging in randomized order. Attenuation and scatter correction were performed using low-dose CT for the PET/CT and segmented Dixon MR imaging data for the PET/MR. Differences between PET/MR and PET/CT were assessed via region-of-interest (ROI)-based and voxel-based statistical group comparison. Analyses involved attenuation-corrected (AC) and non-attenuation-corrected (NAC) data. Individual PET/MR and PET/CT datasets were compared versus a predefined independent control population, using 3-dimensional stereotactic surface projections. RESULTS Generally, lower measured PET signal values were obtained throughout the brain in ROI-based quantification of the PET signal for PET/MR as compared with PET/CT in AC and NAC data, independently of the scan order. After elimination of global effects, voxel-based and ROI-based group comparison still revealed significantly lower relative tracer signal in PET/MR images in frontoparietal portions of the neocortex but significantly higher relative signal in subcortical and basal regions of the brain than the corresponding PET/CT images of the AC data. In the corresponding NAC images, the discrepancies in frontoparietal portions of the neocortex were diminished, but the subcortical overestimation of tracer intensity by PET/MR persisted. CONCLUSION Considerable region-dependent differences were observed between brain imaging data acquired on the PET/MR, compared with corresponding PET/CT images, in patients evaluated for neurodegenerative disorders. These findings may only in part be explained by inconsistencies in the attenuation-correction procedures. The observed differences may interfere with semiquantitative evaluation and with individual qualitative clinical assessment and they need to be considered, for example, for clinical trials. Improved attenuation-correction algorithms and a PET/MR-specific healthy control database are recommended for reliable and consistent application of PET/MR for clinical neuroimaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

18F-FDG PET/CT usefulness vs Tc99m-Tetrofosmin in the assessment of malignant brain gliomas: Report of two cases

Gliomas account for almost 80% of primary malignant brain tumors in adults. Magnetic Resonance imaging (MRI) is still the gold standard for diagnosis of brain tumors and brain 99mTc-tetrofosmin Single Photon Emission Computed Tomography (99mTc-tetrofosmin-SPECT) has been established as a useful tool for their evaluation. Fluorine-18–2-fluoro-2-deoxy-d-glucose positron emi...

متن کامل

The potential value of F-18 FDG PET in comparison to ct in early prediction of response to Imatinib (STI571) therapy in patients with gastrointestinal stromal tumors

  Introduction: Gastrointestinal stromal tumors (GISTs) are the most common mesenchymal neoplasms of the gastrointestinal tract. GIST has been shown to over-express c-KIT (CD117), the receptor tyrosine kinase. Imatinib (STI571 or Glivec) is a new type of tyrosine kinase inhibitor that selectively inhibits various tyrosine kinases and has been successfully used to trea...

متن کامل

Factors influencing the pattern and intensity of myocardial 18F-FDG uptake in oncologic PET-CT imaging

Introduction:Myocardial 18F-FDG uptake is highly variable in oncologic whole body 18F-FDG PET/CT studies, ranging from quite intense to minimal distribution. Intense or heterogeneous myocardial 18F-FDG uptake is undesirable as it may interfere with the visual or quantitative evaluation of tumoral invasion and metastases in pericardium, myocardiu...

متن کامل

Diagnostic performance of 18F-FDG PET-CT in patients presenting with secondary neck nodes from an unknown primary

Introduction: Clinical examination and even anatomical imaging may fail to identify primary site of malignancy in patients presenting with cervical nodal metastasis. 18F-Fluorodeoxyglucose Positron Emission Computed Tomography (18F-FDG PET-CT) is known to overcome the limitations of anatomic imaging. Methods: Sixty-three (63) patient...

متن کامل

The diagnostic difference between 18F- FDG PET and 99mTc-HMPAO SPECT perfusion imaging in assessment of Alzheimer's disease

Introduction:Brain imaging with F-18 fluorodeoxyglucose (18F-FDG) positron ‎emission tomography or Tc-99m hexamethylpropyleneamine oxime (‎99mTc-HMPAO) SPECT is widely used for the evaluation of Alzheimer's ‎dementia (AD); we aim to assess superiority of one method over the ‎other. Methods: Twenty four patients with clinical diagnosi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 55 6  شماره 

صفحات  -

تاریخ انتشار 2014