Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadaveric study and preliminary report.

نویسندگان

  • T Apivatthakakul
  • O Arpornchayanon
  • S Bavornratanavech
چکیده

Minimally Invasive Plate Osteosynthesis (MIPO) has gained popularity with satisfactory clinical outcomes in the treatment of long bone fractures. MIPO for humeral shaft fractures, however, could be a surgically dangerous procedure because of the risk of radial nerve injury. An anatomical study was performed to evaluate the feasibility of MIPO for the humeral shaft fractures, and to study the relationship between the radial nerve and the plate with the forearm in full pronation and in supination. The study was performed on ten arms from five fresh cadavers. Two separate incisions, one proximal and one distal, were made in each arm with the forearm in full supination. A 9-hole narrow DCP was inserted into a tunnel using an anterior approach and fixed with 2 screws each on the proximal and distal humerus. The tunnel was then explored to identify the relationship between the radial nerve and the plate. No radial nerve compression or entrapment by the plate was found. The distance measured from the closest part of the plate to the radial nerve was 2.0-4.9 mm (average 3.2 mm). When the forearm was pronated, the radial nerve moved closer to the plate by a distance of 0-3 mm. The results of this study showed that it is possible to treat humeral shaft fractures by the MIPO method using an anterior approach. To reduce the risk of radial nerve injury, the forearm must be kept in full supination during plate insertion, and excessive force should be avoided during retraction of the lateral half of the brachialis muscle together with the radial nerve in the distal incision. The results of using this MIPO approach for humeral shaft fractures in 4 patients were also reviewed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimally invasive plate osteosynthesis using a helical plate for metadiaphyseal complex fractures of the proximal humerus.

Minimally invasive plate osteosynthesis (MIPO) has been used for humeral shaft fractures, but concerns exist about soft tissue injuries. The purpose of this study was to report the surgical technique and clinical outcomes of MIPO using a helical plate for metadiaphyseal complex humeral shaft fractures. Twelve patients with acute displacement involving proximal and middle third humeral shaft fra...

متن کامل

Comparison of minimally invasive plate osteosynthesis and conventional plate osteosynthesis for humeral shaft fracture

BACKGROUND The objective of this meta-analysis was to compare the efficacy and safety of minimally invasive plate osteosynthesis (MIPO) and conventional plate osteosynthesis (CPO) for humeral shaft fracture. METHODS Potential academic articles were identified from the Cochrane Library, Medline (1966-2016.3), PubMed (1966-2016.3), Embase (1980-2016.3), and ScienceDirect (1966-2016.3). Gray stu...

متن کامل

Minimally invasive plate osteosynthesis vs conventional fixation techniques for surgically treated humeral shaft fractures: a meta-analysis

BACKGROUND In this study, we performed a meta-analysis to identify whether minimally invasive plate osteosynthesis (MIPO) was superior to conventional fixation techniques (CFT) for treating humeral shaft fractures. METHODS A systematic literature search was conducted up to February 2016 in ScienceDirect, Springer, MEDLINE, and PubMed databases for relevant papers that compared the outcomes of...

متن کامل

Effects of different surgical techniques on mid-distal humeral shaft vascularity: open reduction and internal fixation versus minimally invasive plate osteosynthesis

BACKGROUND Humeral shaft fractures are generally managed with the conventional posterior open reduction and internal fixation (ORIF) or minimally invasive plate osteosynthesis (MIPO). This study was aimed at comparing the outcomes of these surgical techniques in terms of the vascular integrity of the mid-distal humeral shaft. METHODS Twelve upper limbs were harvested from 6 fresh cadavers. OR...

متن کامل

Case-Match Controlled Comparison of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing for the Stabilization of Humeral Shaft Fractures.

OBJECTIVES To compare the risk of major complications after either minimally invasive plate osteosynthesis (MIPO) or intramedullary nailing (IMN) of humeral shaft fractures. DESIGN Retrospective, case-match controlled study. SETTING A major metropolitan tertiary referral trauma center in Australia. PATIENTS Thirty patients with fractures of the humeral shaft. INTERVENTION Either MIPO or...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Injury

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 2005