Evaluation of jet nebulisers for use with gentamicin solution.
نویسندگان
چکیده
Recently nebulised antibiotics (gentamicin and carbenicillin) have been used successfully to treat respiratory tract infection in patients with cystic fibrosis. No information exists, however, on the choice of nebuliser or the ideal mode of operation with antibiotic solutions, which are often viscous. The aerosol output, droplet size, and nebulisation time were assessed for four common brands of jet nebuliser (Bird, DeVilbiss, Inspiron, and Upmist) used to nebulise 2 ml (80 mg) and 4 ml (160 mg) of gentamicin solution (Garamycin, Kirby-Warrick) at four compressed gas flow rates (6, 8, 10, and 12 1 . min-1). There were considerable variations between the nebulisers, DeVilbiss and Upmist being most efficient in the release of respirable (less than 5 micron diameter) droplets. Droplet size and nebulisation time were inversely proportional to gas flow rate. Aerosol output and nebulisation time were increased by raising the volume fill from 2 to 4 ml, although nebulisation time could still be restricted to 12 minutes or less with DeVilbiss and Upmist at 12 1 . min-1. The output of drug in droplets of below 5 micron diameter ranged from 7.2 (SE 0.4) to 71.4 (4.3) mg, according to the type of nebuliser, flow rate, and volume fill. These studies suggest that for optimal drug delivery 4 ml gentamicin solution should be nebulised either at a fixed flow rate of 10-12 1 . min-1 or with a high flow compressor. Previous unsatisfactory clinical results with antibiotic aerosols may have been due in part to incorrect choice of nebuliser or inappropriate operating conditions, or both.
منابع مشابه
Jet and ultrasonic nebuliser output: use of a new method for direct measurement of aerosol output.
Output from jet nebulisers is calibrated traditionally by weighing them before and after nebulisation, but the assumption that the weight difference is a close measure of aerosol generation could be invalidated by the concomitant process of evaporation. A method has been developed for measuring aerosol output directly by using a solute (fluoride) tracer and aerosol impaction, and this has been ...
متن کاملNebulisers for patients with HIV infection and AIDS.
bacterium tuberculosis and other opportunistic infections. The choice of nebuliser and delivery system is If nebulisers are to be used within the hospital dictated by the need to deposit pentamidine then nebulisation should be carried out in a in the alveoli and to avoid deposition in the room separate from the main ward area, ideally oropharynx, trachea, and major bronchi. ...
متن کاملNebulisers: uses and abuses.
Jet nebulisers are used to deliver a wide range of drugs as aerosols. The British National Formullarv lists not only six bronchodilator solutions in doses up to 10 mg (available in single dose ampoules, multidose vials, or both), but also one corticosteroid, one prophylactic agent (sodium cromoglycate), and two mucolytics as being suitable for nebulisation.' In addition, nebulisers have been us...
متن کاملWhich apparatus for inhaled pentamidine? A comparison of pulmonary deposition via eight nebulisers.
Aerosolised pentamidine 300 mg in 5 or 6 ml solution was administered via 8 different nebuliser systems to 12 patients with acquired immunodeficiency syndrome. Using 99mTc human serum albumin as an indirect marker for pentamidine, pulmonary, extrapulmonary (gastric and oropharyngeal) and alveolar deposition of pentamidine were measured using a gamma camera. Side effects (visual analogue scales)...
متن کاملRandomised crossover trial of salbutamol aerosol delivered by metered dose inhaler, jet nebuliser, and ultrasonic nebuliser in chronic lung disease.
AIMS To compare the efficacy of salbutamol delivered by metered dose inhaler (MDI), jet nebuliser, and ultrasonic nebuliser in ventilated infants with chronic lung disease. METHODS Twenty preterm ventilated infants with chronic lung disease were enrolled in two studies. In study 1 (n = 10), each infant was given 200 micrograms of salbutamol at 4 hour intervals and in random sequence from a me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 40 9 شماره
صفحات -
تاریخ انتشار 1985