Comparison of Gated and Ungated Black-Blood Fast Spin-echo MRI of Carotid Vessel Wall at 3T
نویسندگان
چکیده
PURPOSE Multi-slice ungated double inversion recovery has been proposed as an alternative time-efficient and effective sequence for black-blood carotid imaging. The purpose of this study is to evaluate the comparative repeatability of this multi-contrast sequence with respect to a single slice double inversion recovery prepared gated sequence. MATERIALS AND METHODS Ten healthy volunteers and three patients with Doppler ultrasound defined carotid artery stenosis >30% were recruited. T1-weighted (T1W) and T2W fast spin-echo (FSE) images were acquired centered at the carotid bifurcation with and without cardiac gating. Repeat imaging was performed without patient repositioning to determine the variations in vessel wall measurement and signal intensity due to gating, while negating variations as a result of slice misalignment and anatomical displacement relative to the receiver coil. The distributions and the repeatability of lumen area, vessel wall area, signal and contrast-to-noise ratio (SNR/CNR) of the vessel wall and adjacent muscle were reported. RESULTS The T1W ungated sequence generally had comparable wall SNR/CNR with respect to the gated sequence, however the muscle SNR was lower (P = 0.013). The T2W ungated multi-slice sequence had lower SNR/CNR than the gated single slice sequence (P < 0.001), but with equivalent effective wall CNR (P = 0.735). Vessel area measurements using the gated/ungated sequences were equivalent. Ungated sequences had better repeatability in SNR/CNR than the gated sequences with borderline and statistically significant differences. The repeatability of T2W wall area measurement was better using the ungated sequences (P = 0.02), and the repeatability of the remaining vessel area measurements were equivalent. CONCLUSIONS Ungated sequences can achieve comparable SNR/CNR and equivalent carotid vessel area measurements than gated sequences with improved repeatability of SNR/CNR. Ungated sequences are good alternatives of gated sequences for vessel area measurement and plaque composition quantification.
منابع مشابه
Comparison between ungated multi-slice and gated single-slice double inversion recovery prepared black-blood fast spin echo sequences applied at 3T
Introduction Multi-contrast high-resolution MRI has been widely used as a method for assessing carotid plaque tissue subtypes [1]. However, its application is still mainly in the research domain. One of the major issues is the long acquisition times required to obtain the multiple contrast weightings at multiple slice locations. Many protocols todate have used ECG-gated, double inversion recove...
متن کاملMulticontrast black-blood MRI of carotid arteries: comparison between 1.5 and 3 tesla magnetic field strengths.
PURPOSE To compare black-blood multicontrast carotid imaging at 3T and 1.5T and assess compatibility between morphological measurements of carotid arteries at 1.5T and 3T. MATERIALS AND METHODS Five healthy subjects and two atherosclerosis patients were scanned in 1.5T and 3T scanners with a similar protocol providing transverse T1-, T2-, and proton density (PD)-weighted black-blood images us...
متن کاملEvaluation of a dedicated dual phased-array surface coil using a black-blood FSE sequence for high resolution MRI of the carotid vessel wall.
PURPOSE To investigate the ability of magnetic resonance imaging (MRI) to visualize the carotid vessel wall using a phased-array coil and a black-blood (BB) fast spin-echo (FSE) sequence. MATERIALS AND METHODS The phased-array coil was compared with a three-inch coil. Images from volunteers were evaluated for artifacts, wall layers, and wall signal intensity. Signal intensity and homogeneity ...
متن کاملAssessment of improved motion-sensitized driven equilibrium (iMSDE) for multi-contrast vessel wall screening.
PURPOSE We assessed the improved motion-sensitized driven equilibrium (iMSDE) technique for multiple contrast 3-dimensional vessel wall imaging at 3T. METHODS Carotid images were obtained using iMSDE combined with turbo field echo (iMSDE-TFE) and conventional double inversion-recovery turbo spin-echo (DIR-TSE) in 5 healthy adult subjects. The tissue signal-to-noise efficiency (SNReff), SNR di...
متن کاملDual stack black blood carotid artery CMR at 3T: Application to wall thickness visualization
BACKGROUND The increasing understanding of atherosclerosis as an important risk factor for the development of acute ischemic events like ischemic stroke has stimulated increasing interest in non-invasive assessment of the structure, composition and burden of plaque depositions in the carotid artery wall. Vessel wall imaging by means of cardiovascular magnetic resonance (CMR) is conventionally d...
متن کامل