Outdoor/indoor Air Quality in Primary Schools in Lisbon: a Preliminary Study

نویسندگان

  • Priscilla Nascimento Pegas
  • Margarita G. Evtyugina
  • Célia A. Alves
  • Teresa Nunes
  • Mário Cerqueira
  • Mariana Franchi
چکیده

OUTDOOR/INDOOR AIR QUALITY IN PRIMARY SCHOOLS IN LISBON: A PRELIMINARY STUDY. Simultaneous measurements of outdoor and indoor pollution were performed at three schools in Lisbon. Volatile organic compounds (VOCs), formaldehyde and NO 2 were passively monitored over a two-week period. Bacterial and fungal colony-forming units and comfort parameters were also monitored at classrooms and playgrounds. The highest indoor levels of CO 2 (2666 μg/m), NO 2 (40.3 μg/m), VOCs (10.3 μg/m), formaldehyde (1.03 μg/m) and bioaerosols (1634 CFU/m), and some indoor/outdoor ratios greater than unity, suggest that indoor sources and building conditions might have negative effects on air indoors. Increasing ventilation rates and use of low-emission materials would contribute towards improving indoor air quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی غلظت ذرات قابل استنشاق در کلاس های مدارس ابتدایی مرکز شهر ساری

Background and purpose: High concentrations of respirable particles in both the outdoor and indoor environments are associated with adverse health effects that could reduce the performance of students. This study was carried out to investigate the indoor concentrations of respirable particle and outdoor concentrations of PM2.5 at classrooms in primary schools in Sari, north of Iran. We also eva...

متن کامل

بررسی غلظت ذرات معلق در هوای داخل کلاس و هوای بیرون و عوامل تأثیرگذار آن در مدارس راهنمایی و دبیرستان شهر یزد

Abstract Introduction: Airborne pollution in such public environments as schools has adverse health effects on pupils and teachers who spend a noticeable amount of time in the school. Therefore, this study aimed to measure the suspended particles concentration of indoor and outdoor air of Yazd schools as well as to determine the influencing parameters on the pollution intensity. Metho...

متن کامل

بررسی غلظت مونواکسیدکربن هوای داخل ساختمان و هوای آزاد شهر بیرجند (شهریور تا اسفند 1393)

Background and Aim: One of the notorious  air pllutants on which air quality is determined is  carbon monoxide (CO). The aim of the present study was to measure the concentration of CO outdoor and indoor urban environments and compare it with air quality standards within buildings  and open spaces. Materials and Methods: This research was a descriptive-analytical study of CO estimation in ou...

متن کامل

Gamma background radiation in Yazd province A preliminary report

 ABSTRACTBackground: There are relatively rich uranium mines in regions of Saghand and Bafgh in Yazd province. This survey was carried out to provide a map of ambient gamma radiation of Yazd province and the probable effects of the existence of these mines on background radiation dose rates.Materials and Methods: The measurements of the outdoor and indoor–environmental exposures (including cosm...

متن کامل

Indoor and Outdoor Air Fungus Bioaerosols in Khorramabad Day Care Child Centers Western of Iran, 2018

Introduction: the aim of this study was to determine the quantity and quality of indoor and outdoor air fungus bioaerosols in Khorramabad day care child centers. Materials and Methods: A total of 180 air samples were collected from 10 centers in 2018. The samples included 7 indoor and 2 outdoor sampling points. The total number of children was 580. Sampling of fungal bioaerosols was performed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010