Optical measurement of isolated canine lung filtration coefficients after alloxan infusion.

نویسندگان

  • J W Klaesner
  • N A Pou
  • R E Parker
  • C Finney
  • R J Roselli
چکیده

In this study, lung filtration coefficient (Kfc) was measured in eight isolated canine lung preparations by using three methods: standard gravimetric (Std), blood-corrected gravimetric (BC), and optical. The lungs were held in zone III conditions and were subjected to an average venous pressure increase of 8.79 +/- 0.93 (mean +/- SD) cmH2O. The permeability of the lungs was increased with an infusion of alloxan (75 mg/kg). The resulting Kfc values (in milliliters . min-1 . cmH2O-1 . 100 g dry lung weight-1) measured by using Std and BC gravimetric techniques before vs. after alloxan infusion were statistically different: Std, 0.527 +/- 0.290 vs. 1. 966 +/- 0.283; BC, 0.313 +/- 0.290 vs. 1.384 +/- 0.290. However, the optical technique did not show any statistical difference between pre- and postinjury with alloxan, 0.280 +/- 0.305 vs. 0.483 +/- 0. 297, respectively. The alloxan injury, quantified by using multiple-indicator techniques, showed an increase in permeability and a corresponding decrease in reflection coefficient for albumin (sigmaf). Because the optical method measures the product of Kfc and sigmaf, this study shows that albumin should not be used as an intravascular optical filtration marker when permeability is elevated. However, the optical technique, along with another means of measuring Kfc (such as BC), can be used to calculate the sigmaf of a tracer (in this study, sigmaf of 0.894 at baseline and 0.348 after injury). Another important finding of this study was that the ratio of baseline-to-injury Kfc values was not statistically different for Std and BC techniques, indicating that the percent contribution of slow blood-volume increases does not change because of injury.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical measurement of isolated canine lung filtration coefficients at normal hematocrits.

In this study, lung filtration coefficient (Kfc) values were measured in eight isolated canine lung preparations at normal hematocrit values using three methods: gravimetric, blood-corrected gravimetric, and optical. The lungs were kept in zone 3 conditions and subjected to an average venous pressure increase of 10.24 +/- 0.27 (SE) cmH2O. The resulting Kfc (ml . min-1 . cmH2O-1 . 100 g dry lung...

متن کامل

Partial liquid ventilation reduces fluid filtration of isolated rabbit lungs with acute hydrochloric acid-induced edema.

BACKGROUND Hydrochloric acid aspiration increases pulmonary microvascular permeability. The authors tested the hypothesis that partial liquid ventilation has a beneficial effect on filtration coefficients in acute acid-induced lung injury. METHODS Isolated blood-perfused rabbit lungs were assigned randomly to one of four groups. Group 1 (n = 6) served as a control group without edema. In grou...

متن کامل

Electron microscopic pathological patterns of alveolar septum in acute dextran-induced and alloxan-induced pulmonary edema in dogs.

We studied the incidence of electron microscopic pathological patterns of the alveolar septum observed 30 min after induction of pulmonary edema by dextran-70 infusion (6 dogs, dextran group) and by alloxan injection (6 dogs, alloxan group). For comparable amounts of extravascular lung water in both dextran and alloxan groups, which were twice as much as control group (6 dogs), we characterized...

متن کامل

Tezosentan reduces the microvascular filtration coefficient in isolated lungs from rats subjected to cecum ligation and puncture

INTRODUCTION We recently demonstrated that the non-selective endothelin-1 (ET-1) receptor blocker tezosentan antagonizes ovine acute lung injury (ALI) following infusion of endotoxin or ET-1 by reducing the enhanced lung microvascular pressure, although we could not exclude the possibility of a simultaneous decline in microvascular permeability. In the present study, our aim was to find out if ...

متن کامل

Measurement of glomerular filtration rate by inulin clearance without urine collection.

A continuous infusion method for measuring inulin clearance (and hence glomerular filtration rate) which does not require urine collection has been re-evaluated and found to give satisfactory results. In two non-oedematous and anephric patients the plasma level of inulin became virtually constant four hours after a single intravenous dose, and hence this is the minimum time required for the inf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 84 4  شماره 

صفحات  -

تاریخ انتشار 1998