Multibed needle trap devices for on site sampling and preconcentration of volatile breath biomarkers.
نویسندگان
چکیده
To facilitate their use in trace gas analysis, the adsorption capacity of needle trap devices (NTDs) was increased by combining three adsorbent materials and increasing total adsorbent amount. The use of 22 gauge needles, application of internally expanding desorptive flow technique without cryofocusation and a new on site alveolar sampling method for NTDs provided sensitivity in the parts per trillion range of VOC concentrations without loosing precision or linearity. LODs were 0.4 ng/L for isoprene, 0.5 ng/L for dimethyl sulphide, 0.9 ng/L for 2-butenal, 1.0 ng/L for hexane, 1.2 ng/L for pentane, 2.3 ng/L for hexanal, 5.3 ng/L for pentanal, and 8.3 ng/L for acetone. R of calibration curves were consistently >0.98. Loss of volatile aldehydes during storage for 7 days was less than 10%. Needle trap devices packed with more than one adsorbent material represent a promising alternative to SPE and SPME for analysis of volatile organic compounds in the low parts per billion/parts per trillion range. Crucial problems of clinical breath analysis concerning sensitivity of analytical methods, limited stability, and decomposition of breath compounds during sampling and storage could be solved.
منابع مشابه
Recent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review
Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...
متن کاملDevelopment of a Method Based on the Needle-trap Microextraction Filled with Hydroxyapatite and Polyaniline Nanocomposite for Determination of Volatile Organic Compounds in the Air
In this study, the efficiency of packed needle trap with hydroxyapatite/polyaniline (NTD-HAP/PA) nanocomposite was assessed in air sampling and analysis of a hazardous group of VOCs such as benzene, toluene, ethylbenzene and xylenes. The effects of main parameters, including desorption temperature and time, were evaluated on the performance and carryover of prepared NTDs. Moreover, the repeatab...
متن کاملکاربرد روش تله سوزنی (Needle Trap) در تعیین مقدار ترکیبات ارگانوهالوژن در هوا
Background and aim s : The correct assessment of volatile organic compounds is a main stage of their control's action plan. Needle trap device (NTD) as a novel technique with all advantages of microextraction methods, is an inexpensive and rapid technique for survey of air pollution agents. In this study the performance of this technique was investigated for sampling and analysis of organohal...
متن کاملارزیابی عملکرد ریز نمونه بردار تله سوزنی حاوی جاذب کامپوزیت سیلیکاته نانولوله کربنی جهت نمونه برداری از پرکلرواتیلن : مطالعه آزمایشگاهی و میدانی
Background and aims: Needle trap micro-sampler, with all advantages of microextraction techniques such as solid phase microextraction, owing to the ease of use and becoming a powerful method for air pollution monitoring. In this study, the performance of needle trap micro-sampler device with silica composite of carbon nanotubes, prepared using sol-gel technique, was investigated for health moni...
متن کاملOptimisation of sampling parameters for standardised exhaled breath sampling.
The lack of standardisation of breath sampling is a major contributing factor to the poor repeatability of results and hence represents a barrier to the adoption of breath tests in clinical practice. On-line and bag breath sampling have advantages but do not suit multicentre clinical studies whereas storage and robust transport are essential for the conduct of wide-scale studies. Several device...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 81 14 شماره
صفحات -
تاریخ انتشار 2009