Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer

نویسندگان

  • Kiyoshi Yaoeda
  • Atsushi Fukushima
  • Motohiro Shirakashi
  • Takeo Fukuchi
چکیده

PURPOSE To investigate the correlation coefficients between intraocular pressure (IOP) before and after adjusting for central corneal thickness (CCT) and corneal biomechanical properties. PATIENTS AND METHODS A total of 218 eyes of 218 patients with primary open-angle glaucoma (mean age =71.5 years; mean spherical equivalent =-0.51 D; mean deviation determined by Humphrey visual field analyzer =-3.22 dB) were included in this study. The tIOP and tIOPCCT, which were adjusted by the CCT (with tIOP meaning IOP not adjusted by CCT, as determined using the CT-1P; and tIOPCCT meaning IOP adjusted by CCT, as determined using the CT-1P), were determined using a noncontact tonometer. The IOPg and IOPCCT, which were adjusted by CCT, and IOPcc adjusted by corneal biomechanical properties were determined using a Reichert 7CR (with IOPg meaning IOP not adjusted by CCT or corneal biomechanical properties, as determined using the Reichert 7CR; IOPCCT meaning IOP adjusted by CCT, as determined using the Reichert 7CR; and IOPcc meaning IOP adjusted by corneal biomechanical properties, as determined using the Reichert 7CR). The GT and GTCCT adjusted by CCT were determined using a Goldmann applanation tonometer (with GT meaning IOP not adjusted by CCT, as determined using the Goldmann applanation tonometer; and with GTCCT meaning IOP adjusted by CCT, as determined using the GAT). Pearson's correlation coefficients among the IOPs were calculated and compared. P-values <0.05 were considered as statistically significant. RESULTS The tIOP, tIOPCCT, IOPg, IOPCCT, IOPcc, GT, and GTCCT were 14.8±2.5, 15.0±2.4, 13.1±3.2, 13.3±3.1, 13.7±2.9, 13.2±2.4, and 13.4±2.3 mmHg (mean ± standard deviation), respectively. The correlation coefficient between tIOPCCT and tIOP (r=0.979) was significantly higher than that between tIOPCCT and the other IOPs (r=0.668-0.852; P<0.001, respectively). The correlation coefficient between IOPCCT and IOPg (r=0.994) or IOPcc and IOPg (r=0.892) was significantly higher than that between IOPCCT or IOPcc and the other IOPs (r=0.669-0.740; P<0.001, respectively). The correlation coefficient between GTCCT and GT (r=0.989) was significantly higher than that between GTCCT and the other IOPs (r=0.669-0.740; P<0.001, respectively). CONCLUSION The IOP adjusted by CCT or corneal biomechanical properties depends on the measurement instrument itself, rather than the adjustment methods, for eyes of patients with primary open-angle glaucoma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

Comparison of intraocular pressure as measured by three different non-contact tonometers and goldmann applanation tonometer for non-glaucomatous subjects

BACKGROUND To compare the measurement of intraocular pressure (IOP) among the three different non-contact tonometers (NCT) and the Goldmann applanation tonometer (GAT) for non-glaucomatous subjects. METHODS In 52 eyes of 52 non-glaucomatous subjects, IOP was measured sequentially with the Canon TX-20P, the Nidek NT-530P, the Topcon CT-1P, and the GAT at the same time. We evaluated the IOP-mea...

متن کامل

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer.

AIMS To investigate the effect of central corneal thickness and corneal curvature on intraocular pressure measurements using the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer, and to assess the agreement between the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer in intraocular pressure measurement. METHODS 479 subjects underwent int...

متن کامل

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

BACKGROUND To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. METHODS Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016